Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-086X
    Keywords: Aneurysm, rupture ; Arteriography ; Middle colic artery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A case of a ruptured middle colic artery is reported. The diagnosis was initially overlooked and eventually made by selective arteriography. Aneurysms of visceral arteries are rare and rupture of them even more infrequent. Awareness of this potentially fatal and treatable entity should enable early detection by selective visceral arteriography. The roles of embolization and surgery in the management of visceral aneurysms are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of legal medicine 108 (1996), S. 237-243 
    ISSN: 1437-1596
    Keywords: Faeces ; Mitochondrial DNA ; Extraction Solid-phase sequencing ; Forensic DNA typing
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Law
    Notes: Abstract A method has been developed for the forensic analysis of faeces by DNA amplification and direct sequencing of a polymorphic segment of mitochondrial DNA. Starting from as little as 10 mg wet weight of faeces, DNA was extracted by a variety of protocols and amplified using primers specific to hypervariable region I of the mitochondrial control region. The resulting amplification products were sequenced in solid phase using an automated DNA sequencer. In total, mtDNA sequences were generated from the faeces of nine Caucasians and compared with sequences generated from their respective blood samples. Sequences of faeces and blood samples from the same individual were identical in every case, but a range of 1–10 nucleotide differences was observed between individuals, with an average sequence variation of approximately 4.88 per 400 bp. Of the various extraction protocols assessed in this study, greatest success rates were achieved using magnetisable beads to bind and purify the DNA. STR analysis of DNA extracted from faeces was not routinely possible.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...