Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 71 (1998), S. 479-486 
    ISSN: 1432-1246
    Keywords: Key words Acoustic rhinometry ; Albumin ; Eosinophil cationic protein ; Indoor air quality ; Lysozyme ; Myeloperoxidase ; Mechanical ventilation ; Nasal obstruction ; School environment ; Sick building syndrome
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objectives: The aim of the present study was to examine the relationships between the ventilation rate and the type of ventilation system, on the one hand, and objective nasal measures, on the other. Methods: A standardized investigation, including acoustic rhinometry and nasal lavage, was performed in the school environment. All 279 school personnel working in the main buildings of 12 randomly selected primary schools in the municipality of Uppsala were invited, and 234 (84%) participated. The dimensions of the nasal cavity were measured with acoustic rhinometry. Eosinophil cationic protein (ECP), myeloperoxidase (MPO), lysozyme, and albumin were analyzed in the lavage fluid. The air exchange rate and the room temperature were measured in the classrooms. Relationships between nasal symptoms, nasal patency, and the concentration of biomarkers, on the one hand, and the type of ventilation system, the air exchange rate, and the temperature, on the other, were analyzed by both crude bivariate analysis and multiple regression models, controlling for the type of ventilation, the air exchange rate, room temperature, age, gender, smoking, atopy, and the urban vicinity of the school. Results: A lower degree of nasal patency as measured by acoustic rhinometry and increased levels of ECP and lysozyme in nasal lavage were associated with a lower air exchange rate in the schools. Although mechanically ventilated schools had higher air exchange rates, they were associated with more nasal symptoms, and nasal mucosal swelling and with increased lavage levels of ECP and lysozyme as compared with schools with natural ventilation only. In contrast, 12 subjects working in a school with mechanical displacement ventilation had more patent noses and lower levels of inflammatory markers as compared with the personnel in schools with natural ventilation only. Conclusion: Our results indicate that both a low air exchange rate and mechanical ventilation systems based on dilution can be associated with reduced nasal patency and an inflammatory biomarker response of the nasal mucosa among school personnel. The only school with sufficient ventilation according to the current Swedish recommendations had a displacement system and the fewest signs of nasal reactions among the personnel.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 72 (1999), S. 507-515 
    ISSN: 1432-1246
    Keywords: Key words Follow-up study ; Nasal lavage ; Acoustic rhinometry ; Newly painted indoor surfaces ; Albumin ; Eosinophilic cationic protein ; Myeloperoxidase ; Lysozyme ; Indoor air quality ; Ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Introduction: There is a need to evaluate possible health effects of ventilation improvements and emissions from new buildings, in longitudinal studies. New methods to study biological effects on the eyes and upper airways are now available. Material and methods: A longitudinal study was performed on 83 trained social workers in two offices in Uppsala, Sweden. The exposed group (n= 57) moved to a newly redecorated building nearby. Low emitting building material had been used, including a new type of solvent-free water-based paint. The control group (n= 26) worked in the same office during the study period (November 1995 to February 1996). Hygiene management was carried out in both offices, at the beginning and the end of the investigation. Tear film stability (BUT) was measured. Nasal patency was measured by acoustic rhinometry, and eosinophilic cationic protein (ECP), myeloperoxidase (MPO), lysozyme and albumin were analyzed in nasal lavage fluid (NAL). Results: The relocation resulted in an increase in the personal outdoor airflow rate from 11 to 22 l/s. Indoor concentrations of terpenes were higher in the new building, and powdering of the new linoleum floor was observed. Measurements showed low levels of volatile organic compounds (VOC), formaldehyde, carbon dioxide (CO2), nitrogen dioxide, respirable dust, and microorganisms in the air of all buildings. The move resulted in an increased nasal patency and an increase of ECP and lysozyme in NAL, after adjusting for changes in the control group. No changes were observed for nasal or ocular symptoms. A seasonal effect, with a decrease of ECP, was observed in the control group. Conclusion: A well-ventilated office building can be redecorated without any major ocular or nasal effects, or measurable increase of indoor air pollution if low-emitting building materials are selected. In agreement with previous evidence, the improved ventilation flow may explain the increase of nasal patency. The increase of ECP and lysozyme in NAL suggested an inflammatory effect in the new building. Since this building had increased ventilation flow, increased concentrations of terpenes, and powdering from the polish on the new linoleum floor, identification of causative agents was difficult. The hygiene measures did not give any evidence that emissions from the new type of solvent-free water-based paints or building dampness were responsible for the observed nasal effects. Considering the higher emissions of VOC reported from older types of water-based latex paints and solvent-based wall paints, the new type of solvent-free water-based paint seems to be a good choice from the hygiene point of view.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...