Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1572-9508
    Keywords: cosmology ; balloon-borne instrumentation ; infrared detection ; cryogenics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A cooled telescope (250 mm, F/2) has been designed and prepared for measurements of both local and cosmological Near Infrared backgrounds in the waveband 1–5 μm at balloon altitudes (40 km). The separation of various foreground contributions should be possible by applying observing strategies based on multiple sky scans with different filters. The whole apparatus will be tested in flight by using a detection system based on a linear array of 32 InSb pixels cryogenically cooled and thermally controlled at 52 K. The instrument sensitivity will allow the measurement of most of the local backgrounds. The focal plane could be easily re-arranged to house bidimensional array detectors cooled down to ∼ 35 K with performance improvements of a factor at least 100 ÷ 200. A description is given of the main characteristics of the instrument (optics, cryostat, detector), of the control subsystems (cryogenics, pointing systems, electronics, ground equipment) and of the expected performance based on laboratory test results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 22 (1984), S. 426-432 
    ISSN: 1741-0444
    Keywords: Inert vapours and gases ; N-compartment model ; Pulmonary elimination ; Uptake regulation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A mathematical model is presented which provides analytical solutions for the uptake regulation and pulmonary elimination of inert vapours and gases. The results obtained are in extremely good agreement with both experimental data and the exact numerical solutions usually suggested in the literature. In particular, some analytical solutions to correlate the behaviour of the gas concentration in the tissues with the various physiological parameters during the uptake regulation and desorption have been obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...