Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 217-222 
    ISSN: 1040-7685
    Keywords: capillary isotachophoresis ; diode laser ; concentration gradient detector ; universal detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A diode laser-based, universal concentration gradient detector was applied to capillary isotachophoresis (CITP). The inexpensive CITP instrument also included a 30 cm long, 300 μm i.d. capillary, a 5 cm focal length lens and a photodiode light beam position sensor. Factors affecting the sensitivity and performance of the detector, i.e., separation conditions, spatial resolution of the detector, and the concentration of leading electrolyte, were discussed theoretically and experimentally. The diode laser-based concentration gradient detector appears to be one of the best detectors for CITP due to its high resolution, derivative nature, and low cost. The experimental detection limit reached 4 × 10-6 M for small cations, which was near the theoretical value. The detection limit can be further reduced by at least one order of magnitude if a longer capillary is used. The CITP-concentration gradient detector instrument has high efficiency, and was applied to detect impurities in antidepressant drugs.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 2290-2295 
    ISSN: 0173-0835
    Keywords: Capillary isoelectric focusing ; Imaging detection ; On-line desalting ; Tapered capillary ; Protein analysis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Capillary isoelectric focusing (CIEF) is a high resolution technique for protein separation. The on-column single point detector requires a mobilization step which lengthens the analysis time and causes an uneven resolution along the separation column. The real time and whole column imaging detection has been developed for performing CIEF without mobilization. Three types of imaging detection systems have been developed: optical absorption, refractive index gradient, and laser induced fluorescence. This technique provides a fast analysis speed (about 6 min) and a good resolution of 0.03 pH unit level. Using the absorption imaging detector, ampholyte-free IEF in tapered capillary is being demonstrated, which eliminates the interference of the expensive carrier ampholytes for protein detection in UV region. Recent advancements in this imaged CIEF technique as well as its applications are reviewed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...