Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 397-401 
    ISSN: 1040-7685
    Keywords: isoelectric focusing ; cone shaped capillaries ; pH gradient ; temperature gradient ; proteins ; absorption imaging detection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A simple method of generating pH gradients for use in capillary isoelectric focusing was described and evaluated experimentally. In the proposed scheme, the cone shaped capillary filled with a conventional buffer is used to produce an effect of nonuniform heating which then generate temperature and corresponding pH gradients along the capillary axis. Concentration and separation of proteins by applying a simple isoelectric focusing system based on this principle is demonstrated. An inexpensive absorption imaging detection system is used to continuously monitor progress of the separation and concentration processes.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 2290-2295 
    ISSN: 0173-0835
    Keywords: Capillary isoelectric focusing ; Imaging detection ; On-line desalting ; Tapered capillary ; Protein analysis ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Capillary isoelectric focusing (CIEF) is a high resolution technique for protein separation. The on-column single point detector requires a mobilization step which lengthens the analysis time and causes an uneven resolution along the separation column. The real time and whole column imaging detection has been developed for performing CIEF without mobilization. Three types of imaging detection systems have been developed: optical absorption, refractive index gradient, and laser induced fluorescence. This technique provides a fast analysis speed (about 6 min) and a good resolution of 0.03 pH unit level. Using the absorption imaging detector, ampholyte-free IEF in tapered capillary is being demonstrated, which eliminates the interference of the expensive carrier ampholytes for protein detection in UV region. Recent advancements in this imaged CIEF technique as well as its applications are reviewed.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...