    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 20 (1982), S. 727-733 
    ISSN: 1741-0444
    Keywords: Biomechanical stability ; External fixation ; Pelvic fractures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract The effectiveness of external fixation in the stabilisation of pelvic ring fractures was studied in a laboratory cadaveric series. Shearing displacements occurring at sacroiliac joint and symphysis pubis dislocation sites, due to simplified longitudinal loading of the sacrum in an Instron unit, were monitored using variable-impedence transducers. The rigidity of fixation was compared for the Slätis and the Bonnel single anterior frames, for coupled and uncoupled double anterior frames, and for combined anterior-plus-posterior fixation achieved with separate transfixation pin clusters, with through-and-through pin clusters, or with a posterior screw plate. The data showed that the use of posterior fixation provided greatly enhanced stabilisation compared to that achieved with anterior fixation alone. The complex double anterior frames performed only slightly better than did the simpler single anterior frames. In no case, however, was it possible to recover rigidity levels approaching those of the intact pelvis. The results suggest that the transfixation pin arrangement is the most important determinant of pelvic fixation stability, and that further investigation of posterior screw-plate fixation is warranted.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 21 (1983), S. 657-663 
    ISSN: 1741-0444
    Keywords: Biomechanical stability ; External fixation ; Pelvic fractures
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract A laboratory cadaveric model, developed previously for the study of currently employed external fixation devices used for unstable pelvic fractures was used to evaluate rigidity improvements associated with a number of fixation design innovations. Based on quasistatic shearing displacements measured at the sacro-iliac joint and symphysis pubis disruption sites, otherwise identical anterior frameworks constructed on 5 mm fixation halfpins, rather than upon standard 4 mm halfpins, were able to sustain markedly (58% to 210%) greater loadings. A new and very simple traingular framework was designed and constructed for which the fixation rigidity was found to rival that of much more complex and cumbersome double anterior frames. When used as the posterior component of combined anterior/posterior fixation systems, a new double cobra-type (internal) plate allowed the injury model pelvises to sustain near-physiological load levels. A pair of dynamic compression plates attached across a disrupted symphysis pubis was found to be a biomechanically acceptable substitute for an anterior external fixator.