Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (1)
  • Thrombosis, renal artery, angioscopy  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Transplant international 7 (1994), S. 65-66 
    ISSN: 1432-2277
    Keywords: Angioscopy, renal transplantation ; Renal transplantation, angioscopy ; Thrombosis, renal artery, angioscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Poor back-table perfusion of a renal allograft may occur as a result of intravascular thrombosis of the renal artery branches. We herein report such a case where back-table angioscopy was performed to confirm the diagnosis, followed by successful thrombolysis using urokinase under hypothermic conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this study was to determine the effects of endothelial cell seeding and graft internodal distance upon the performance of 4-mm-ID e-PTFE grafts during acute reduced blood flow conditions. PTFE grafts especially manufactured with three different mean internodal distances (28, 40, and 52 μm) were evaluated. Fifteen dogs (n = 5 for each design of PTFE graft) underwent bilateral carotid artery replacements with 6 cm lengths of 4-mm-ID PTFE grafts. In each dog one graft was seeded with enzymatically derived endothelial cells; the contralateral graft was nonseeded. All grafts were evaluated 5 weeks postoperatively. Dogs with bilaterally patent grafts were subsequently subjected to flow conditions through the graft that were maintained at 30% of the initial flow rates for 4 hr. Following controlled low flows the grafts were excised and assessed for patency, thrombus-free surface area, inner capsule thickness and prostacyclin production. Endothelial cell seeding of these small-diameter e-PTFE vascular grafts improved patency and thrombus-free surface areas in grafts of all pore sizes, with these parameters being greatest in the 40-μm grafts. Inner-capsule healing in these grafts was controlled and related to the pore size. PGI2 production was improved in endothelial cell seeded grafts of all pore sizes. However, neither endothelial cell seeding nor graft pore size affected the performance of these e-PTFE grafts under conditions of reduced blood flows.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...