Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1433-0350
    Keywords: Hydrocephalus ; Transcranial Doppler ; Pulsatility index ; Resistance index ; Intracranial pressure ; Anterior fontanel pressure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cerebral hemodynamic changes in infants with progressive hydrocephalus have been studied with the transcranial Doppler (TCD) technique. Several authors have referred to the correlation between the hemodynamic changes and increased intracranial pressure (ICP). Despite conflicting conclusions on the value of pulsatility index (PI) measurements for monitoring infantile hydrocephalus, these pulsatility indices are the most commonly used for this purpose. Although clinical signs of raised ICP are highly variable and unreliable in infants, assumptions have been made in most of the studies about the presence of elevated ICP on the basis of the patient's clinical state. Few studies have reported on actual ICP values, however, and a direct relationship between ICP and TCD changes has never been adequately demonstrated. In the present study, this relationship was investigated in long-term simultaneous TCD/ICP measurements, in an attempt to develop a noninvasive method of monitoring the effect of ICP on intracranial hemodynamics. Two groups of data sets were established. Group I consisted of pre- and postoperative (shunt implantation) TCD/ICP measurements. Group II were long-term simultaneous TCD/ICP recordings showing significant ICP variations. In most of the postoperative measurements there was a decrease in the average PI and RI values. The correlation between PI or RI and ICP in the long-term simultaneous recordings, however, was generally poor. The risk of obtaining false positive or false negative PI or RI values in short-term measurements was also demonstrated. It can be concluded from our results, besides the wide range of reference values for the Doppler indices and extracranial influences upon them, that the present Doppler indices are inadequate for monitoring the complex intracranial dynamic responses in patients with raised ICP.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...