Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Retention behavior  (1)
  • fluorescence enhancement  (1)
  • graphitic carbon stationary phases  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 590-594 
    ISSN: 0935-6304
    Keywords: Ion chromatography ; graphitic carbon stationary phases ; anions ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: ---Inorganic anions could be separated on porous graphitic carbon stationary phases in ion chromatography. Ion exchange between eluent anions and sample anions on the stationary phase was confirmed by the retention behavior and the possibility of indirect photometric detection. The elution order of anions was different from that observed for commercially available anion exchangers. Chloride, nitrate, and sulfate contained in tap water could be determined in 7 min.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1040-7685
    Keywords: liquid chromatography ; γ-cyclodextrin ; bovine serum albumin ; fluorescence enhancement ; retention behavior ; dansyl amino acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effects of γ-cyclodextrin and bovine serum albumin as mobile phase additives on fluorescence intensity and retention of dansyl amino acids (Dns-AAs) have been examined in microcolumn liquid chromatography. Polymercoated mixed-functional silica packings were employed for the separation column. The concentrations of the additives, acetonitrile, and buffer affected the signal intensity and retention of DNA-AAs. The use of the mobile phase additives improved the detection limits by a factor of as much as 7.4. © 1995 John Wiley & Sons, Inc.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Cation-exchange-induced stationary phases ; Retention behavior ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The retention behavior of aromatic hydrocarbons and dansylamino acids on cation-exchangers modified with alkylammonium ions has been examined by microcolumn liquid chromatography. Several parameters affected the retention of analytes, involving concentration of the modifier in the mobile phase, its alkyl chain length and mobile phase composition. Stationary phases modified with a reagent having longer alkyl chains achieved better column efficiency.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability