Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1106
    Keywords: Key words Focal cerebral ischemia ; Photothrombosis ; Reperfusion ; Spontaneous recanalization ; Cerebral blood flow ; Edema ; Penumbra ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  In clinical thromboembolic stroke, spontaneous late recanalization is a common feature, but one which has been very sparsely studied experimentally. This study aimed at enabling the study of spontaneous reperfusion and exploring its consequences by modifying a recently developed photothrombotic-stroke model that focuses on the region-at-risk located within an ischemic ring-locus. The exposed crania of male Wistar rats (280–340 g) were subjected to a ring-shaped (5.0 mm outer diameter and 0.35 mm thick) laser-irradiation beam (514.5 nm; 0.89 W/cm2) for 2 min simultaneously with intravenous erythrosin B (17 mg/kg) infusion for 30 s. Transcardial carbon-black perfusion experiments revealed a ring-shaped cortical perfusion deficit at 4 h post-irradiation, which progressively increased at 10, 24, and 48 h, at which time the whole region-at-risk was pale with single distal branches of the middle cerebral artery being extensively narrowed, but not occluded. At 72 h, spontaneous reperfusion was observed in the region-at risk, which was even more pronounced at 7 and 28 days. Cortical cerebral blood flow (cCBF), measured by laser-Doppler flowmetry, was distinctly reduced at 2 min post-irradiation and further decreased slightly during 4 h of recording to ca. 24% of baseline values at the ring locus and 40% in the region-at-risk. In the region-at-risk, cCBF flow values were 23–30% of the baseline at 24–48 h post-irradiation, followed by a relative cCBF increase to 71 and 77% at 72 and 96 h post-irradiation. Brain water content in the ischemic part of the cortex increased steadily from 4 to 48 h post-irradiation; at 72 h, it leveled off and returned to control values at 7 days. In conclusion, by employing a laser beam in the shape of a thin ring, critically sustained cCBF reduction was followed by late, consistent spontaneous reperfusion in the region-at-risk in this novel photochemically induced stroke-in-evolution model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...