Library

Your search history is empty.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 6 (1988), S. 425-433 
    ISSN: 0736-0266
    Keywords: Surface replacement ; Prosthesis design ; Finite elements ; Stress shielding ; Porous ingrowth ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Three different interface geometries for porous ingrowth surface replacements of the hip were examined using two-dimensional linear and non-linear contact finite element analyses. The results indicate that incorporation of a nearly flat prosthesis interface between the surface replacement and the underlying cancellous bone may reduce stress shielding and improve stress transfer from the component. For all designs analyzed, the bone stress shielding was insensitive to component material stiffness when the elastic modulus was 〉30 MPa. The use of titanium instead of cobalt-chrome (Co-Cr) as the prosthesis material therefore had a negligible effect on stress shielding.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 5 (1987), S. 296-299 
    ISSN: 0736-0266
    Keywords: Torsion ; Warping ; Internal fixation ; Bone plating ; Stress shielding ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: Torsion of noncircular beams results in warping of each cross section. When noncircular cross sections are constrained to remain plane, the resulting shear stress distribution is different from what Saint Venant torsion (with warping) would predict. This has practical implications to the stress analysis of plated long bones subjected to torsional loadings. Analyses in which warping is not allowed predict incorrect stress fields in the plate and bone and overpredict the amount of stress shielding associated with fracture plate fixation.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource