Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 67-71 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A technique has been developed to determine the absolute single particle counting efficiency of a channel electron multiplier (CEM) for positively charged ions at keV energies. The calibration technique is applicable to positive ion detectors in general. Ion beam currents of C2+ were created by charge transfer of C3+ on H2 in the thin target regime. By adjusting the H2 pressure in the beam scattering chamber from 10−10 to 10−6 Torr, C2+ currents could be created either low enough to be detected by the CEM in the particle counting mode or high enough to be measured as a current using the CEM as a Faraday cup. The CEM counting efficiency was determined by comparing the C2+ count rate to the C2+ current, scaling by the change in H2 pressure, and also scaling by the incident C3+ current for each C2+ measurement. This method, which effectively uses the charge transfer cross section as a "transfer standard,'' allows the CEM counting efficiency to be determined in situ and to be monitored accurately over extended periods of time. The calibration requires that only the relative, not the absolute, pressure change be known. The technique does not require the value of the charge transfer cross section to be known. The accuracy of the calibration technique for the present results was 10% at a confidence level considered to be equivalent to a statistical 90% confidence level. For the present work, the peak counting efficiency of a Galileo 4039 CEM for 32.5 keV C2+ ions was determined to be 96%. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 2254-2265 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An inclined beams apparatus for the measurement of absolute cross sections for dielectronic recombination between free electrons and singly or multiply charged ions is described. The collision products, a photon and a lower-charge-state ion, are detected in delayed coincidence. Measurements of dielectronic recombination in C3+ are described to illustrate the use of the apparatus and techniques. Verification of the calibrations and operation of the apparatus is demonstrated through measurements of charge transfer and electron impact excitation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 383-392 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An ion beam apparatus for the absolute measurement of collision cross sections in singly and multiply charged ions is described. An inclined electron and ion beams arrangement is used. Emitted photons from the decay of collision produced excited states are collected by a mirror and imaged onto a photomultiplier. Absolute measurements of the electron impact excitation of the 2s–2p transition in C3+ were used to demonstrate the reliability of the apparatus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 57 (1986), S. 177-184 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: An apparatus is described for studying the photodissociation of neutral free radicals and positive molecular ions with a fast beam technique. Particular attention is given to studies of diatomics whose constituent atoms have very different masses and to photodissociation of polyatomic systems. Novel features of this design include fast neutral beam generation by photodetachment of negative ions, beam energies sufficiently high to detect neutral products, and a beam filter for reducing noise from background processes. A position-sensitive detector provides the data required to determine separation energies and angular distributions for dissociation studies where only one fragment is detectable.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1573-093X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The SOHO Ultraviolet Coronagraph Spectrometer (UVCS/SOHO) is being used to observe the extended solar corona from 1.25 to 10 R⊙ from Sun center. Initial observations of polar coronal holes and equatorial streamers are described. The observations include measurements of spectral line profiles for HI Lα and Lβ, Ovi 1032 Å and 1037 Å, Mgx 625 Å, Fexii 1242 Å and several others. Intensities for Mgx 610 Å, Sixii 499 Å, and 520 Å, Sx 1196 Å, and 22 others have been observed. Preliminary results for derived H0, O5+, Mg9+, and Fe11+ velocity distributions and initial indications of outflow velocities for O5+ are described. In streamers, the H0 velocity distribution along the line of sight (specified by the value at e-1, along the line of sight) decreases from a maximum value of about 180 km s-1 at 2 R⊙ to about 140 km s-1 at 8 R⊙. The value for O5+ increases with height reaching a value of 150 km s-1 at 4.7 R⊙. In polar coronal holes, the O5+ velocity at e-1 is about equal to that of H0 at 1.7 R⊙ and significantly larger at 2.1 R⊙. The O5+ in both streamers and coronal holes were found to have anisotropic velocity distributions with the smaller values in the radial direction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1573-093X
    Keywords: Sun ; Solar Corona ; Solar Wind ; UV Spectroscopy ; UV Coronagraph
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The SOHO Ultraviolet Coronagraph Spectrometer (UVCS/SOHO) is composed of three reflecting telescopes with external and internal occultation and a spectrometer assembly consisting of two toric grating spectrometers and a visible light polarimeter. The purpose of the UVCS instrument is to provide a body of data that can be used to address a broad range of scientific questions regarding the nature of the solar corona and the generation of the solar wind. The primary scientific goals are the following: to locate and characterize the coronal source regions of the solar wind, to identify and understand the dominant physical processes that accelerate the solar wind, to understand how the coronal plasma is heated in solar wind acceleration regions, and to increase the knowledge of coronal phenomena that control the physical properties of the solar wind as determined byin situ measurements. To progress toward these goals, the UVCS will perform ultraviolet spectroscopy and visible polarimetry to be combined with plasma diagnostic analysis techniques to provide detailed empirical descriptions of the extended solar corona from the coronal base to a heliocentric height of 12 solar radii.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-093X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The Ultraviolet Coronagraph Spectrometer on the SOHO satellite covers the 940–1350 Å range as well as the 470–630 Å range in second order. It has detected coronal emission lines of H, N, O, Mg, Al, Si, S, Ar, Ca, Fe, and Ni, particularly in coronal streamers. Resonance scattering of emission lines from the solar disk dominates the intensities of a few lines, but electron collisional excitation produces most of the lines observed. Resonance, intercombination and forbidden lines are seen, and their relative line intensities are diagnostics for the ionization state and elemental abundances of the coronal gas. The elemental composition of the solar corona and solar wind vary, with the abundance of each element related to the ionization potential of its neutral atom (First Ionization Potential–FIP). It is often difficult to obtain absolute abundances, rather than abundances relative to O or Si. In this paper, we study the ionization state of the gas in two coronal streamers, and we determine the absolute abundances of oxygen and other elements in the streamers. The ionization state is close to that of a log T = 6.2 plasma. The abundances vary among, and even within, streamers. The helium abundance is lower than photospheric, and the FIP effect is present. In the core of a quiescent equatorial streamer, oxygen and other high-FIP elements are depleted by an order of magnitude compared with photospheric abundances, while they are depleted by only a factor of 3 along the edges of the streamer. The abundances along the edges of the streamer (‘legs’) resemble elemental abundances measured in the slow solar wind, supporting the identification of streamers as the source of that wind component.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1572-9672
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We made streamer observations with the Ultraviolet Coronagraph Spectrometer (UVCS) on the Solar and Heliospheric Observatory (SOHO) during the early part of 1998, which was a time of moderate solar activity. We present an empirical study of coronal ion kinetics using the line profiles from these observations. Our first and most striking result is that the mid-latitude (ML) streamers have much narrower O VI 1032 Å line profiles than the solar minimum equatorial (SME) streamers. Our second result is that the line profiles from a small collection of ions in ML streamers do not seem to be consistent with the ions having a single temperature and turbulent velocity. We discuss several interpretations, including line of sight (LOS) effects. This work is supported by the National Aeronautics and Space Administration under grant NAG-3192 to the Smithsonian Astrophysical Observatory.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1572-9672
    Keywords: corona ; solar wind ; UV radiation ; spectroscopy ; line profiles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Ultraviolet emission line profiles have been measured on 15-29 September 1997 for H I 1216 Å, O VI 1032, 1037 Å and Mg X 625 Å in a polar coronal hole, at heliographic heights ϱ (in solar radii) between 1.34 and 2.0. Observations of H I 1216 Å and the O VI doublet from January 1997 for ϱ = 1.5 to 3.0 are provided for comparison. Mg X 625 Å is observed to have a narrow component at ϱ = 1.34 which accounts for only a small fraction of the observed spectral radiance, and a broad component that exists at all observed heights. The widths of O VI broad components are only slightly larger than those for H I at ϱ = 1.34, but are significantly larger at ϱ = 1.5 and much larger for ϱ 〉 1.75. In contrast, the Mg X values are less than those of H I up to 1.75 and then increase rapidly up to at least ϱ = 2.0, but never reach the values of O VI.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1572-9672
    Keywords: corona ; solar wind ; UV radiation ; spectroscopy ; line profiles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract We constrain coronal outflow velocity solutions, resolved along the line-of-sight, by using Doppler dimming models of H I Lyman alpha and O VI 1032/1037 Å emissivities obtained with data from the Ultraviolet Coronagraph Spectrometer (UVCS) on SOHO. The local emissivities, from heliocentric heights of 1.5 to 3.0 solar radii, were determined from 3-D reconstructions of line-of-sight intensities obtained during the first Whole Sun Month Campaign (10 August to 8 September 1996). The models use electron densities derived from polarized brightness measurements made with the visible light coronagraphs on UVCS and LASCO, supplemented with data from Mark III at NCAR/MLSO. Electron temperature profiles are derived from 'freezing-in' temperatures obtained from an analysis of charge state data from SWICS/Ulysses. The work concentrates on neutral hydrogen outflow velocities which depend on modeling the absolute coronal H I Lyα emissivities. We use an iterative method to determine the neutral hydrogen outflow velocity with consistent values for the electron temperatures derived from a freezing-in model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...