Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 8 (1987), S. 295-302 
    ISSN: 0197-8462
    Keywords: microwaves ; ambient temperature ; bacterial infection ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Female CD-1 mice were injected with an LD50 dose of Streptococcus pneumoniae and then exposed to 2.45 GHz (CW) microwave radiation at an incident power density of 10 mW/cm2 (SAR = 6.8 W/kg), 4 h/d for 5 d at ambient temperatures of 19 °C, 22 °C, 25 °C, 28 °C, 31 °C, 34 °C, 37 °C and 40 °C. Four groups of 25 animals were exposed at each temperature with an equal number of animals concurrently sham-exposed. Survival was observed for a 10-d period after infection. Survival of the sham-exposed animals increased as ambient temperature increased from 19 °C-34 °C. At ambient temperatures at or above 37 °C the heat induced in the body exceeded the thermoregulatory capacity of the animals and deaths from hyperthermia occurred. Survival of the microwave-exposed animals was significantly greater than the shams (∼20%) at each ambient temperature below 34 °C. Based on an analysis of the data it appears that the hyperthermia induced by microwave exposure may be more effective in increasing survival in infected mice than hyperthermia produced by conventional methods (ie, high ambient temperature). Microwave radiation may be beneficial to infected animals at low and moderate ambient temperatures, but it is detrimental when combined with high ambient temperatures.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 7 (1986), S. 91-94 
    ISSN: 0197-8462
    Keywords: microwaves ; immunology ; antibody response ; mice ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Female CD-1 mice immunized against the bacterium Streptococcus pneumoniae type III were exposed to 9-GHz pulsed microwaves (pulse repetition rate 970-1,000, pulse width 1.0 μs, peak power 1 W/cm2) at an average incident power density of 1 mW/cm2 (calculated SAR = 0.47 W/kg) for 2 h per day for 5 days. Circulating antibody titers for the microwave-exposed animals were not significantly different from those of the shamirradiated animals, and there were no differences in any of the hematological parameters analyzed, indicating that 9-GHz pulsed microwaves at 1 mW/cm2 do not alter the immune response of mice immunized against S pneumoniae.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 1 (1980), S. 397-404 
    ISSN: 0197-8462
    Keywords: antibody response ; microwaves ; immunology ; 9-GHz pulsed radiation ; infectivity ; mouse ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A significant increase was observed in the circulating antibody titers of mice exposed to 9-GHz pulsed microwaves at an average power density of 10 mW/ cm2, two hours per day for five days compared with sham-irradiated animals. The mice were previously immunized with type III pneumococcal polysaccharide. Following irradiation, a portion of the immunized animals were challenged with virulent Streptococcus pneumoniae, type III. Ten days after challenge, mortality was essentially the same in the two groups, but during the ten day period, there was a noticeable increase in the survival time of the irradiated animals compared with the sham-irradiated animals, suggesting that the increased circulating antibody response afforded some degree of temporary protection to the animals.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...