Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • antiprotonic X-rays  (1)
  • cascades  (1)
  • muonic hydrogen  (1)
Materialart
Erscheinungszeitraum
  • 1
    ISSN: 1572-9540
    Schlagwort(e): X-ray spectroscopy ; exotic atoms ; antiprotonic X-rays ; pion mass
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Some time after its formation an exotic atom may be considered a hydrogen-like system consisting of a nucleus and an exotic particle in a bound state. In this situation it is an ideal tool to study cascade properties, while for the innermost orbits it can be used to probe the interaction with the nucleus. From an extended series of experiments using high resolution X-ray spectroscopy for both aspects typical examples are reported and preliminary results are given: 1. To determine the complex scattering length in $${\bar p}$$ H the $${\text{3D}} \to 2{\text{P}} $$ hyperfine transitions have been measured. 2. To determine the pion mass the 5 $$\to $$ 4 transitions in $$\pi ^{14} $$ N have been studied. In all cases a major contribution to the uncertainty originates from the calibration. Therefore a new method is proposed that will establish a universal set of high precision calibration lines for pionic, muonic and electronic systems.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1572-9540
    Schlagwort(e): proton ; proton radius ; muon ; muonic hydrogen ; Lamb shift
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract The contribution of the root mean square (RMS) proton charge radius to the Lamb shift (2S–2P energy difference) in muonic hydrogen (μp) amounts to 2%. Apart from the uncertainty on this charge radius, theory predicts the Lamb shift with a precision on the ppm level. We are going to measure ΔE (2 S1/2(F=1)–2 P3/2(F=2)) in a laser resonance experiment to a precision of 30 ppm (i.e., 10% of the natural linewidth) and to deduce the RMS proton charge radius with 10−3 relative accuracy, 20 times more precise than presently known. The most important requirement for the feasibility of such an experiment, namely the availability of a sufficient amount of long lived metastable μp atoms in the 2S state, has been investigated in a recent experiment at PSI. Our analysis shows that in the order of one percent of all muons stopped in low pressure hydrogen gas form a long lived μp(2S) with a lifetime of the order of 1 μs. The technical realization of our experiment involves a new high intensity low energy muon beam, an efficient low energy muon entrance detector, a randomly triggered 3 stage laser system providing the 0.5 mJ, 7 ns laser pulses at 6.02 μm wavelength, and a combination of a xenon gas proportional scintillation chamber (GPSC) and a microstrip gas chamber (MSGC) with a CsI coated surface to detect the 2 keV X rays from theμp(2P → 1S) transition.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Hyperfine interactions 119 (1999), S. 83-88 
    ISSN: 1572-9540
    Schlagwort(e): muonic atoms ; cascades ; molecular effects ; X-ray spectroscopy
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract Muonic X-ray cascades in B, C, N, O and Ne following muonic atom formation in B2H6, CH4, C2H6, C4H10, N2, O2 and Ne were investigated. The densities of the different target gases were low enough to prevent any contact of the atom or molecule on which the formation takes place with surrounding atoms or molecules during the cascade. Molecular effects of the capturing molecule are clearly seen. The observed transition yields could be reproduced by variation of only two parameters in a cascade calculation: the number of initially available electrons and the muon angular momentum distribution at the starting point of the calculation. By varying the number of electrons, the molecular effects could be described.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...