Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of interventional cardiac electrophysiology 2 (1998), S. 285-292 
    ISSN: 1572-8595
    Keywords: catheter ablation ; cryoablation ; arrhythmias ; atrioventricular node
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated the feasibility of using cryogenic technology in an electrode catheter for percutaneous ablation of cardiac tissue. Despite its high success rate, radiofrequency catheter ablation has important limitations especially with regards to the treatment of ventricular arrhythmias associated with a chronic scar. Arrhythmia surgery experience has shown that freezing with a hand held probe can permanently ablate the arrhythmogenic substrate of ventricular tachycardia associated with an old scar. Moreover, cryosurgery also allows for reversible “ice mapping,” in which the area likely responsible for the arrhythmia can be evaluated by suppressing its electrophysiologic properties prior to the creation of an irreversible state. A new steerable cryoablation catheter using Halocarbon 502 as a refrigerant was utilized in six dogs. Serial cryoapplications were performed in the right and left ventricles. In two dogs, we attempted reversible ice mapping of the AV node. Pathological evaluation of the lesions was done acutely in all the animals. Forty-two cryoapplications were delivered at a mean temperature of −45 ± 9.8°C. No lesion was found at pathological evaluation for 16 cryoapplications which did not achieve a temperature of less (colder) than −30°C. The remaining applications resulted in 26 lesions which were hemorrhagic and sharply demarcated from normal myocardium. Histological evaluation revealed contraction band necrosis. Reversible ice mapping of the AV node was successfully achieved in two animals. Cryoablation is feasible using an electrode catheter with multiple electrodes. This technology has the potential to allow for reversible ice mapping to confirm a successful ablation target before definitive ablation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...