Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-4994
    Keywords: Voltage-sensitive dye ; optical fiber ; fluorescence ; lobster axon ; frog heart ; laser
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract With the use of a single, implantable, optical fiber, to excite fluorescence and detect changes from voltage-sensitive dyes, transmembrane potential changes were measured without the need for a clear line-of-sight path between the excitation light, the tissue, and the detector. In a previous study, we were required to use signal averaging and could detect only cardiac action potentials from frog. In the present study we improved this system so that unaveraged cardiac action potentials were resolved with high fidelity, and action potentials from single nerve axons were detected. Endeavors to optimize the signal-to-noise ratio resulted in the selection of a larger core fiber with a rounded tip, styryl dyes, and filters based upon fluorescence spectra of the dyes when bound to membrane (rather than in solution). The frog gave signals nearly comparable in magnitude and signal-to-noise ratio to those seen with systems that use a fluorescence microscope. Action potential-induced signals could be detected in single lobster axons with the intracellular injection of a dye. The improvement in the signal-to-noise ratio allowed the use of a reduced-intensity excitation illumination which produced less bleaching of the dye.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 21-42 
    ISSN: 0197-8462
    Keywords: biomolecules ; DNA ; microwave absorption ; optical method ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Direct determination of the microwave absorption characteristics of biological molecules in solution by an optical heterodyne technique is described. A visibly transparent sample is irradiated in a spatially nonuniform manner with pulsed microwaves, and the spatial variation in temperature increase measured by detecting the phase chirp impressed on a single-frequency He—Ne laser beam passing through the heated region. Results for several liquids and solutions such as water, methanol, various saline solutions, and solutions of DNA and DNA sodium salt in water are described. Where direct comparison is possible the results agree very well with published values. A significant increase in the absorption of DNA solutions compared with pure water has been observed that is consistent with microwave absorption by the longitudinal mode of the double helix.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 18 (1997), S. 439-445 
    ISSN: 0197-8462
    Keywords: ELF ; magnetic fields ; calcium ; jurkat ; flow-cytometry ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: To explore possible biochemical mechanisms whereby electromagnetic fields of around 0.1 mT might affect immune cells or developing cancer cells, we studied intracellular calcium signaling in the model system Jurkat E6-1 human T-leukemia cells during and following exposure to a 60 Hz magnetic field. Cells were labeled with the intracellular calcium-sensitive fluorescent dye Fluo-3, stimulated with a monoclonal antibody against the cell surface structure CD3 (associated with ligand-stimulated T-cell activation), and analyzed on a FACScan flow-cytometer for increases in intensity of emissions in the range of 515-545 nm. Cells were exposed during or before calcium signal-stimulation to 0.15 mTrms 60 Hz magnetic field. The total DC magnetic field of 78.2 μT was aligned 17.5° off the vertical axis. Experiments used both cells cultured at optimal conditions at 37 °C and cells grown under suboptimal conditions of 24 °C, lowered external calcium, or lowered anti-CD3 concentration. These experiments demonstrate that intracellular signaling in Jurkat E6-1 was not affected by a 60 Hz magnetic field when culture and calcium signal-stimulation were optimal or suboptimal. These results do not exclude field-induced calcium-related effects further down the calcium signaling pathway, such as on calmodulin or other calcium-sensitive enzymes. Bioelectromagnetics 18:439-445, 1997. © 1997 Wiley-Liss, Inc. This article is a US Government work and, as such, is in the public domain in the United States of America.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...