Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 2 (1990), S. 293-299 
    ISSN: 1040-7685
    Keywords: multidimensional separations ; two-dimensional separations ; CZE ; capillary electrophoresis ; peptide fingerprinting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Comprehensive two-dimensional reversed-phase HPLC-capillary electrophoresis (RP HPLC-CE) was used to compare the tryptic digest fingerprints of horse heart cytochrome C and bovine heart cytochrome C. The peptide fragments were labeled with fluorescamine and detected with a fluorescence detector. The two-dimensional separation system proved to be reproducible enough to identify some species differences in the tryptic digest fingerprints. Improvements in instrumentation and daily procedures yielding faster analysis times and better reproducibility compared to a previous system are described. Improvements in software yielding gray-scale images of the two-dimensional data are described. Identification of selected tryptic fragments was achieved.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 1 (1989), S. 41-45 
    ISSN: 1040-7685
    Keywords: capillary electrophoresis ; mobility ; diffusion coefficient ; proteins ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary zone electrophoresis can be used to determine mobilities and diffusion coefficients for analytes. Mobilities are determined from measurements of migration times. Correction for electroosmotic flow must be made by measuring the flow magnitude using an uncharged marker substance. Diffusion coefficients can be measured from peak widths of analyte bands. Care must be taken in these measure- ments that the analyte concentration does not overload the system and perturb the axial homogeneity of the electric field strength. Analyte also must not adsorb to the surface of the capillary. Finally, the capillary should be operated with a power dissipation that is low enough that minimal heating of the capillary occurs. Capillary zone electro- phoresis offers some advantages over other methods of determining mobilities and diffusion coefficients. These include a requirement of only small quantities of analyte at relatively low concentrations and the capability of making measurements on several substances simultaneously in mixtures.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 1 (1989), S. 125-130 
    ISSN: 1040-7685
    Keywords: micellar electrokinetic capillary chromatography ; capillary electrophoresis ; isotopic separations ; micellar separations ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Near-baseline resolution of dansylated methylamine and dansylated methyld3-amine can be achieved by micellar electrokinetic capillary chromatography (MECC) utilizing a 25-mM sodium dodecylsulfate pseudostationary phase and a mobile phase containing 4.9 M methanol. This study examines the role of methanol on this separa- tion by looking at its effects on to, tr,tm, and resolution over four methanol concentrations, 0 M, 2.5 M, 4.9 M, and 7.4 M. The 4.9 M methanol buffer proves to be the best for optimizing the resolution of these two extremely similar compounds. Because of the high organic content of the mobile phase, it is unreliable to determine tm based upon the migration time of a single species. A method for determining tm based upon a homologous series of standards is presented and examined over the four methanol concentrations. Plots of log k′ versus carbon number yield straight lines with similar slopes for each of the four buffer systems, indicating that this procedure is a good method for tm determination.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗