Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1573-8744
    Keywords: theophylline ; absorption ; bioavailability ; sustained release ; tablets ; plasma concentrations ; mean plasma concentrations ; steady-state projections
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Absorption of theophylline from three commercial products labeled as sustained release was compared to the absorption from a standard uncoated tablet (Searle 200-mg aminophylline tablet) in a single-dose study. Aminodur tablets (Cooper) and Slophyllin Gyrocap capsules (Dooner) had bioavailability (100.2%±19.8% and 98.5%±13.8%) statistically indistinguishable from that of the standard but showed significantly slower absorption (peak times of 10,4±2.8 and 4.36±1.35 hr) and lower peak plasma concentrations (13.9±4.5 and 22.6±3.5gmg/ml/g dose) than the standard (t peak ,1.52±0.45 hr; Cpeak,28.l±6.2μg/ml/g dose). The time of the plasma concentration peak (2.47±1.38 hr) after a dose of Tedral S.A. (Warner/Chilcott) was not statistically different from that after the standard, but both the peak concentration (16.0±3.9 gmg/ml/g dose) and bioavailability (76.0±18.4%) were. Multiple-dose projections from single-dose data indicate that of the three test products only Aminodur maintains reasonably constant interdose plasma levels during 12 hourly dosing. With an 8 hourly dosing schedule Gyrocaps also might be satisfactory. Reasonable predictions of the plasma concentrations arising from Aminodur doses have been made using a single-compartment body model and assuming input from an outer followed by an inner layer of the tablet. Typically a single dose of a preparation designed for constant release of drug over 12 hr should not produce a plasma concentration plateau in subjects with an average 6.1-hr drug half-life. The apparent plateau in the mean plasma profile (i.e., concentrations at each sampling time averaged over all subjects) for Aminodur doses is evaluated. The interpretation commonly being implied in the publication of mean profiles from bioavailability studies is misleading, particularly when applied to sustained-release preparations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-8744
    Keywords: theophylline ; intraindividual variability ; within-individual variability ; clearance ; volume
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Bioavailability studies are commonly undertaken, and most, because they involve subjects taking repeated doses of a drug, contain information on intraindividual variability in pharmacokinetics. However, because in such studies bioavailability itself is unknown, it is difficult to resolve which pharmacokinetic parameters vary within individuals. A mathematical model is presented which permits estimation of variability in clearance and in volume of distribution. When applied to pooled data arising from five theophylline bioavailability studies, this model has given statistical evidence that clearance of theophylline is inherently more variable within individuals (coefficient of variation, 13%) than volume of distribution (8%). As a result, use of the measurement AUC ·β rather than AUCas a more precise index of bioavailability is justified in studies where β is measured with reasonable precision. The model could be applied to estimation of withinbatch within-person variability in bioavailability.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...