ISSN:
0197-8462
Keywords:
human
;
calorimetry
;
dielectric heaters
;
Life and Medical Sciences
;
Occupational Health and Environmental Toxicology
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Biology
,
Physics
Notes:
The heat uptake that resulted from immersing the hand and wrist into a water-filled calorimeter maintained at temperatures between 37-40 °C was measured under standard conditions in a group of eight subjects of either sex. The rate of heat transfer (W) increased exponentially with temperature and was a function of hand or body size and age, but not sex. The heat transfer rate normalized to hand mass (W.kg-1) was determined by temperature and age: best-fit mean values (and 95% confidence limits of the population) were 6.0 W.kg-1 (3.2-11.2 W.kg-1) at an immersion temperature of 37 °C and 25.4 W.kg-1 (13.7-47.0 W.kg-1) at 40 °C. The application of these results to limits on specific energy absorption rate induced in the hands and wrists by radiofrequency dielectric heat sealer welders is discussed.
Additional Material:
1 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/bem.2250100108
Permalink