Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
Materialart
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 80 (1996), S. 3622-3627 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: An atomic force microscope (AFM) design providing a focused spot of order 7 μm in diameter was used to analyze the motion of vibrating cantilevers in liquid. Picking an operating frequency for tapping mode AFM operation in liquid is complex because there is typically a large number of sharp peaks in the response spectrum of cantilever slope amplitude versus drive frequency. The response spectrum was found to be a product of the cantilever's broad thermal noise spectrum and an underlying fluid drive spectrum containing the sharp peaks. The geometrical shape of transverse cantilever motion was qualitatively independent of the fluid drive spectrum and could be approximately reproduced by a simple theoretical model. The measurements performed give new insights into the behavior of cantilevers during tapping mode AFM operation in liquid. © 1996 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Small cantilevers allow for faster imaging and faster force spectroscopy of single biopolymers than previously possible because they have higher resonant frequencies and lower coefficients of viscous damping. We have used a new prototype atomic force microscope with small cantilevers to produce stable tapping-mode images (1 μm×1 μm) in liquid of DNA adsorbed onto mica in as little as 1.7 s per image. We have also used these cantilevers to observe the forced unfolding of individual titin molecules on a time scale an order of magnitude faster than previously reported. These experiments demonstrate that a new generation of atomic force microscopes using small cantilevers will enable us to study biological processes with greater time resolution. Furthermore, these instruments allow us to narrow the gap in time between results from force spectroscopy experiments and molecular dynamics calculations. © 1999 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 66 (1995), S. 2582-2584 
    ISSN: 1077-3118
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: A magnetic force microscope (MFM) was used to image topography and magnetic forces from a chain of submicron single magnetic domain particles produced by and contained in isolated magnetotactic bacteria. The noncontact magnetic force microscope data were used to determine a value for the magnetic moment of an individual bacterial cell, of order 10−13 emu, consistent with the average magnetic moment of bacteria from the same sample, obtained by superconducting quantum interference device magnetometry. The results represent the most sensitive quantification of a magnetic force microscope image to date. © 1995 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...