Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 11
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: AutoCapture™ based on the evoked response can be confounded by electrode polarization. In this study, polarization was measured in human subjects who had chronic atrial leads. The aim of the study was to determine whether electrode polarization can be measured using a time integral atrial evoked-response integral (AERI) of the negative portion of the atrial paced ER evoked-response signal and to determine whether high-polarization atrial leads unsuitable for AutoCapture™ can be identified a priori. Atrial intracardiac-electrogram (IEGM) signals from 39 patients with implanted pacemakers were recorded and analyzed. The signals were recorded during conventional atrial-threshold searches. A total of 221 atrial-capture thresholds were recorded, ranging from 0.25 to 2.75 V with a mean of 0.79 V. Each evoked response was evaluated using the AERI in a 36 ms window following the 0.4 ms atrial stimulus. The polarization was estimated as a linear function of stimulus voltage using the evoked-response signal integral of captured beats identified on the IEGM. The 221 threshold-search datasets were obtained using leads with eight different electrode materials. Polarization could be measured using AERI as a function of stimulus voltage. Furthermore, this polarization measure can be used to identify high-polarization leads, which are ill suited for the atrial AutoCapture™ algorithm.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , U.S.A . : Blackwell Publishing
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The aim of the study was to evaluate the time course of atrial and ventricular function improvement following internal atrial cardioversion in patients with structural heart disease. Twenty-nine patients with chronic persistent atrial fibrillation (AF) and underlying structural heart disease were followed by serial echocardiograms performed at 1 and 6 hours, 1 day, 1, 2, and 3 weeks, and 1, 2, 3, and 6 months after successful cardioversion. Sinus rhythm was maintained at 6 months in 24 patients. Following cardioversion the time course of left atrial mechanical function (peak A wave, percent A wave filling) differed from that of left ventricular ejection fraction: peak A wave values (cm/s) increased significantly at 1 week ( 51 ± 23 vs 35 ± 15 at 1 hour, P 〈 0.05 ), percent A wave filling (%) increased significantly at 2 weeks ( 34 ± 12 vs 22 ± 9 at 1 hour, P 〈 0.05 ), whereas left ventricular ejection fraction (%) increased later (at 1 month 60 ± 14 vs 55 ± 14 at baseline, P 〈 0.05 and at 2 months 60 ± 14 vs 56 ± 14 at 1 hour, P 〈 0.05 ). In conclusion, restoration of sinus rhythm results in an improvement in left ventricular ejection fraction during follow-up, even in patients with structural heart disease without fast ventricular rates at baseline. The dissociation between the time course of atrial and ventricular function improvement suggests that the latter was partly due to regression of a concealed form of cardiomyopathy and/or of a ventricular dysfunction due to chronic AF. (PACE 2003; 26:1218–1226)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: GASPARINI, M., et al.: Cardiac Resynchronization and Implantable Cardioverter Defibrillator Therapy: Preliminary Results From the InSync Implantable Cardioverter Defibrillator Italian Registry. The aim of this study was to evaluate ventricular arrhythmias occurring in recipients of the InSync ICD for the primary and secondary prevention of sudden death. The InSync ICD was implanted in 142 patients (128 men; mean age65 ± 10years) with heart failure (mean NYHA functional Class3.0 ± 0.7) and wide QRS (mean159 ± 33ms). The underlying etiology was ischemic in 55%, idiopathic in 33%, and valvular or hypertensive cardiomyopathy in 12% of patients. The numbers of arrhythmic episodes/100 patient-months was computed with their 95% CI, assuming a Poisson distribution. Implants were performed in 48 (34%) patients who did not have an ACC/AHA guidelines Class I indication for ICD therapy. A total of 104 patients were compliant for follow-up visits. During a 9-month median (range 0.1–24) follow-up of 104 compliant patients, 19 experienced a total of 94 ventricular arrhythmias, all successfully interrupted or selfterminated, with a median number of two separate episodes, corresponding to a rate of 10 episodes/100 person-month (95% CI 8–12). A rate of 12 episodes/100 person-months (95% CI 10–15) was measured in the subgroup of patients with ACC/AHA class I indications, versus two episodes/100 person-months (95% CI 1–5) in the remainder of the population. Among 12 deaths, 9 were due to heart failure, 1 to a noncardiovascular cause, and 2 to unknown causes. The implantation of ICD in heart failure patients has been prominently extended to primary prevention. Patients without standard ICD indications experienced life-threatening arrhythmic events. The impact of ICD combined with cardiac resynchronization therapy on arrhythmic profile, mortality, and costs in this subgroup of patients need to be more precisely studied, with a particular focus on the various types of underlying heart disease. (PACE 2003; 26:[Pt. II]:148–151)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: BIFFI, M., et al.: Abnormal Cardiac Innervation in Patients with Idiopathic Ventricular Fibrillation. Idiopathic ventricular fibrillation (VF) is diagnosed in up to nearly 10% of survivors of out-of-hospital cardiac arrest. The arrhythmogenic substrate is unknown. This study examined the role of cardiac innervation as a possible contributor to this arrhythmia. Eight patients with idiopathic VF were compared with eight normal subjects (controls) by [123] I metaiodobenzylguanidine SPECT (MIBG), measuring peak uptake, late uptake, and clearance of the nuclear tracer. The left ventricle was divided in 13 segments in the bull's-eye target plot. Peak and late MIBG uptake was increased in the anterolateral segments (2,3,7,8) compared to the inferoposterior and septal segments, in controls and in patients. No difference was observed between controls and patients in the inferoposterior and septal segments. In contrast, a significantly higher MIBG uptake was observed in patients compared to controls in the anterolateral segments ( 94 ± 4% vs 81 ± 11%, P 〈 0.03 for peak uptake; 94 ± 5% vs 79 ± 12%, P 〈 0.01 for late uptake). No difference was observed in MIBG clearance in any segment in either study group. Cardiac sympathetic innervation is highly heterogeneous, though predominant in anterolateral segments in normal subjects. Patients with idiopathic VF exhibit the same distribution, though have a significantly greater density of sympathetic terminals in the anterolateral segments than controls, which may promote ventricular arrhythmias. (PACE 2003; 26[Pt. II]:357–360)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 22 (1999), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The aim of this study was to evaluate the efficacy of low energy internal atrial cardioversion in restoring sinus rhythm (SR) in patients with chronic atrial fibrillation (AF) persisting 〉 1 year. Fifteen patients with chronic AF lasting 〉 1 year (from 13–48 months, mean 24 ± 13 months) were studied. R wave synchronized 3/3 ms biphasic shocks were delivered between right atrial and coronary sinus (left pulmonary artery in five patients) electrodes. Sedatives or anesthetics were administered only at the patient's request. Results: Stable SR was restored in 14 (93%)of 15 patients after shocks with a mean leading edge voltage of 377 ± 77 V (range 260–500) and a mean delivered energy of 7.3 ± 3.4 J (range 2.6–12.9). The procedure was performed without anesthesia in 6 (40%) patients. All successfully cardioverted patients were treated with flecainide, sotalol, or amiodarone. During a follow up of 7.7 ± 7.9 months (range 1–24) AF recurred in five (36%) patients. Three of five AF recurrences occurred within 3 days after conversion to SR. Conclusion: Internal low energy atrial cardioversion is highly effective in restoring SR even in patients with AF lasting 〉 1 year. The long-term results from the standpoint of freedom from AF recurrences, are satisfactory, although additional antiarrhythmic treatment is required, particularly in the first days after conversion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The efficacy and safety of propafenone as an oral loading dose (600-mg single oral dose) in converting recent-onset atrial fibrillation (≤ 7 days duration) to sinus rhythm were evaluated in a single-blind, placebo-controlled study according to patients' age. Overall, 240 hospitalized patients, NYHA Class ≤ 2 without signs or symptoms of heart failure were enrolled: among patients aged ≤ 60 years, 55 were allocated to propafenone treatment and 59 to placebo, respectively, and among patients aged 〉 60 years, 64 were allocated to propafenone treatment and 62 to placebo, respectively. Results: In each age group, the likelihood of conversion to sinus rhythm was significantly greater after propafenone compared with plocebo at 3 and 8 hours. For patients aged ≤ 60 years, corresponding odd ratios were 3.78 (95% CI = 1.80–7.92, P = 0.04) at 3 hours and 4.74 (95% CI = 2.12–10.54, P = 0.02) at 8 hours; for patients aged 〉 60 years odd ratios were 5.03 (95% CI = 2.08–12.12, P = 0.02) at 3 hours and 6.75 (95% CI = 3.28–73.86, P = 0.01) at 8 hours, respectively. Logistic regression analysis showed that conversion to sinus rhythm within 3 hours was predicted by age ≤ 60 years (P = 0.0064) and by propafenone treatment (P 〈 0.0001), and conversion to sinus rhythm within 8 hours was predicted by age ≤ 60 years (P = 0.0467) and by propafenone treatment (P 〈 0.0001). The occurrence of adverse effects was observed in 14%-16% of propafenone treated patients and in 8% of placebo treated patients without significant differences according to age. In conclusion, in patients with recent-onset atrial fibrillation without signs of heart failure, propafenone as a single oral loading dose is effective. It is also effective in selected elderly subjects with a favorable safety profile. Moreover, spontaneous conversion to sinus rhythm appears to occur less frequently in elderly patients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 16 (2005), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: The pattern of FF intervals during atrial fibrillation (AF) has been analyzed in induced and spontaneous AF episodes, after the induction of ventricular fibrillation (VF) and after atrial shock, in order to suggest practical considerations for AF management in patients implanted with antitachycardia devices. Methods: In 13 patients implanted with a dual-chamber defibrillator, FF intervals were analyzed during two separate induced AF episodes, before and after VF induction over AF, as well as during spontaneous AF episodes and after unsuccessful atrial shocks. The following parameters were considered: mean atrial cycle length (CL), atrial CL stability, and standard deviation of the atrial cycle. Results: The AF pattern had comparable characteristics considering two separate inductions of AF, as well as spontaneous AF episodes. Ventricular tachyarrhythmia induction resulted in a shortening of atrial CL (P 〈 0.02) and in a less organized AF pattern (P 〈 0.005). Changes in the FF interval after ineffective shock therapy showed a shortening of AF cycles after shocks with energies far below the defibrillation threshold. Conclusions: (a) The AF pattern is reproducible in separate inductions of sustained AF and in spontaneous episodes, (b) dynamic changes involving a shortening of the AF cycle and an evolution to a less homogeneous pattern occur after VF induction, revealing a complex interplay between AF and VF, and (c) FF interval analysis after ineffective shock delivery may allow the relationship between delivered shock energy and effective defibrillation energy to be estimated, thereby providing practical suggestions for step-up protocols in atrial cardioversion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: Recent options to treat atrial tachyarrhythmias (ATA) include implantable devices delivering antitachycardia pacing therapies (ATP). No prospective study selected patients with higher chances of episode termination by ATP or indicated the most effective ATP use. Our aim was to study ATP efficacy in patients with brady-tachy form of sinus node disease (SND), identifying clinical factors, ATA characteristics, and device features predicting ATP efficacy. Methods and Results: Three hundred and sixteen patients (105 M, aged 71.1 ± 8.8 years) received a DDDRP pacemaker and were prospectively followed. Median follow-up was 18 months: 37,125 ATA episodes occurred in 217 patients; ATP treated 5,536 of them. Overall, ATP efficacy was 50.0%. A multivariate analysis identified longer arrhythmia cycle lengths (OR = 1.25; CI = 1.07-1.47) and shorter delays to ATP delivery (OR = 0.15; CI = 0.10-0.22) as independent predictors of ATP efficacy for episodes preceded by ≥5 minutes of sinus rhythm. Additionally, ATP efficacy for all treated episodes was predicted by lower New York Heart Association (NYHA) class (OR = 0.64; CI = 0.42-0.98), episode classification as nonimmediate recurrence of ATA (non-IRAT) (OR = 0.07; CI = 0.02-0.33), absence of overlap in the device detection windows (OR = 0.54; CI = 0.32-0.91), and flecainide treatment (OR = 2.22; CI = 1.04-4.71). Conclusions: In patients paced for SND, multivariate analysis shows that ATP efficacy is associated to longer arrhythmia cycle lengths, shorter ATP delivery delays, NYHA class I, episode classification as non-IRAT, absence of overlap in the atrial arrhythmia device detection windows, and flecainide treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 15 (2004), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: New-generation pacemakers allow continuous atrial tachyarrhythmia (AT) monitoring that provides accurate information about AT type, frequency, burden, and temporary evolution. Methods and Results: We performed a prospective multicenter study to describe AT temporal patterns in patients with sinus bradycardia and AT. Two hundred forty patients (123 men; age 71 ± 8 years) were implanted with a DDDRP pacemaker (model AT500, Medtronic Inc.). All patients were followed for 13 months. The first-month stabilization period of all patients was discarded from analysis. Seventy percent of patients had AT recurrences. Mean time to first AT recurrence (48.2 days, 95% confidence interval [CI] 37.0–59.5 days) was significantly longer than the time between first and second AT episode (10.3 days, 95% CI 6.7–13.9 days, P 〈 0.01). A minority of patients had a uniform time distribution of AT recurrences: 〈25% of patients had AT episodes in more than 6 of the 12 months considered in the study. The probability density function of consecutive sinus rhythm days between AT episodes was calculated for each of 40 patients who experienced 〉25 AT episodes and fitted by power law and exponential functions. The best fit was obtained by power law function in 60% of patients, by exponential function in 10%, and the two models gave comparable results in 30% of patients. Conclusion: In our population of patients with a history of sinus bradycardia and AT who were implanted with a new device equipped with atrial pacing therapies, 30% did not experience AT recurrences in the 12-month study period. Analysis of interevent time showed that in 60% of patients AT recurrences do not follow a uniform or random distribution. These findings bring into question the use of cross-over design and time to first AT recurrence as a clinical outcome in trials for AT therapy in this patient population. (J Cardiovasc Electrophysiol, Vol. 15, pp. 44-51, January 2004)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: De. brillation Threshold in Chronic and Reinduced AF. Introduction: Induced versus spontaneous atrial fibrillation (AF) is of interest for assessing atrial defibrillation threshold reproducibility. Methods and Results: Twenty-one patients with chronic AF underwent internal cardioversion with assessment of atrial defibrillation threshold at baseline and at reinduced AF. High right atrial (HRA) and coronary sinus (CS) bipolar recordings were analyzed to measure the mean local atrial period, its coefficient of variation, the 5th (P5) and 95th (P95) percentiles of atrial intervals, and the percentage of points lying at the baseline (number of occurrences), and to quantify AF organization. Atrial defibrillation threshold was comparable in baseline and reinduced AF in terms of leading-edge voltage and delivered energy. Baseline and reinduced AF were comparable with regard to overall signal parameters (both in HRA and CS) and the presence of an organized arrhythmia pattern. As for individual variables, P5 increased while P95 and coefficient of variation decreased in reinduced AF compared with spontaneous AF (statistical significance was achieved for all these parameters in HRA, but only for coefficient of variation and P95 in CS). Conclusion: Sustained AF reinduced after cardioversion of chronic AF is comparable with baseline AF in terms of atrial defibrillation threshold, atrial cycle length, and pattern of organization. Therefore, a clinical model based on reinduction of sustained AF after cardioversion is suitable for studying the effects of a series of interventions on atrial defibrillation threshold. However, because this model does not yield a form of AF with comparable indices of local refractoriness (e.g., P5), it is not recommended when analyzing local electrophysiologic properties.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...