Library

You have 0 saved results.
Mark results and click the "Add To Watchlist" link in order to add them to this list.
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 54 (1984), S. 191-194 
    ISSN: 1432-1106
    Keywords: Baclofen ; Polysynaptic reflexes ; Spasticity ; Intrathecal injection ; Rabbit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Intrathecal baclofen is effective in reducing polysynaptic spinal reflexes in awake rabbits. A single lumbar infusion of 2.5–5.0 ng drug caused a significant reduction in the crossed extensor response to electrical stimulation of the plantar surface of the hindlimb. This inhibition lasted 5 h or more. At doses of 3 μ or less, the forelimbs were unaffected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 33 (1987), S. 99-108 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Human blood (blood bank, expired) sheared through stainless steel capillary tubing (508 μm ID) is analyzed for plasma hemoglobin to study the effect of shear-induced blood damage within the low-stress regime (stress ≤ 20 Pa). Blood damage results are described in terms of capillary length (related to blood residence time) and wall shear rate for assessing bulk and surface effects. A phenomenological model is proposed to explain these experimental results, obtained over a shear rate range to 7,000 s-1.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 30 (1984), S. 569-577 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Human blood is sheared in cone-and-plate and parallel-plate rotational viscometers, the latter with variable plate spacings h. Plasma is analyzed for hemoglobin and LDH content before and after shearing to determine the extent of shear-induced blood damage within the low-stress regime (stress ≤ 13 Pa). Geometrical variations in the test apparatus can be accommodated by correlating blood damage with the radially-averaged shear rate. Data on expired blood are shown to imply that much of the damage arises in the bulk fluid, with a smaller contribution from surface effects. Models are proposed to explain these results, obtained over a shear rate range to 5,000 s-1; parallel-plate platen separation is 0.25 〈 h 〈 1.00 mm, cone-and-plate angle is 0.5°, and both systems have platens 100 mm in diameter.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...