Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 388 (1982), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 338 (1980), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 101 (2000), S. 233-246 
    ISSN: 1573-2622
    Keywords: binocular vision ; Fourier analysis ; strabismus ; temporal frequency ; visual evoked potential (VEP)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The purpose of this work was to study the second harmonic in the steady state pattern visual evoked potential (ssVEP) to various stimulus frequencies in subjects with normal and defective binocularity. ssVEPs were elicited by 4 c/deg sinusoidal gratings, with temporal frequencies ranging from 5 to 20 Hz (exp. 1) and 15 to 27.5 Hz (exp. 2). Responses were Fourier analysed and power and phase of the second harmonic to stimulus frequency were measured. For power, binocular enhancement in a bimodal fashion was found both in normals and in subjects with defective binocularity. The power with binocular stimulation was significantly higher in the normal group in the high frequency domain. Latency, estimated from the phase-frequency function, was longer in the group with defective binocularity, but this was statistically significant only for the high frequency domain. The results suggest that a visual system with normal binocular function can follow a stimulus with high temporal frequency more accurately than a system with disturbed binocularity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 79 (1992), S. 187-194 
    ISSN: 1573-2622
    Keywords: Latency ; spatial frequency ; suprathreshold contrast ; visual evoked potential
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The latency in the visual evoked potential was measured at spatial frequencies of 2–12 c/deg in 10 subjects. The contrast levels of the sinuosoidal grating patterns were set at 1.5, 1.75, 2.0, 2.25, 2.5, 2.75 and 3.0 log units above each subject's contrast sensitivity threshold. Two factors were shown to influence the latency: suprathreshold contrast and, to a lesser extent, spatial frequency. The visual evoked potential latencies at contrast sensitivity threshold were extrapolated. These threshold latencies showed considerable variation with spatial frequency and between subjects. Therefore, the visual evoked potential latency cannot be considered a useful tool for estimating the contrast sensitivity function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1573-2622
    Keywords: Age-related macular degeneration ; Eccentric viewing ; Low vision training
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A new approach designed to establish the most suitable area for eccentric viewing and to teach and train patients with severe age-related macular degeneration (AMD) to use the eccentric viewing technique is described. Using a computer and video display based system, as well as software written specifically for this purpose, we investigated and trained ten consecutive patients with AMD. The patients were 80.1 ± 5.6 years old, on average. All of them had an absolute central scotoma. Mean visual acuity was 0.035 ± 0.016. After 30 min of testing, instruction and reading on the screen, followed by 2.6 ± 0.69 one-hour training sessions, on average, with the low vision therapist, reading newspaper and book texts with the aid of hyperoculars or aplanatic systems and a very short reading distance, the patients achieved a reading speed of 58.9 ± 19.7 words/min, significantly (p〈0.001) higher than the initial speed when reading on the screen, 11.5 ± 4.5 words/min.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...