Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Angewandte Makromolekulare Chemie 212 (1993), S. 103-119 
    ISSN: 0003-3146
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Unterschiedliche Methoden zur Messung der thermo-oxidativen Stabilität von Polypropylen wurden verglichen. Die Induktionszeiten des oxidativen Abbaus wurden mittels Differentialkalorimetrie (DSC) zwischen 160 und 240°C bis zu 10000 min gemessen. Die gleichen Proben wurden bei 130 bis 160°C 13000 h einer Alterung im Heizofen ausgesetzt.Unterschiedlich stabilisierte Proben ergaben bei dynamischen DSC-Messungen unterschiedliche Ergebnisse. Die Übereinstimmung zwischen dynamischen und statischen Experimenten waren bei kleinen Heizraten am besten.Die Arrhenius-Diagramme der isothermen DSC-Messungen unterscheiden sich von denen der Alterungsversuche; die erhaltenen Geraden schneiden sich entweder in der Nähe der Polypropylen-Schmelzpunkte oder verschieben sich bei den durch Temperung gealterten Proben zu längeren Zeiten. Die scheinbaren Aktivierungsenergien aus den Ofen-Temperungsmessungen sind sehr vie1 niedriger als die aus den DSC-Messungen berechneten und liegen bei allen Proben in einem einheitlichen Bereich, während bei den DSC-Experimenten ein Einfluß des Stabilisators zu erkennen ist.Die thermische Stabilität von Polypropylen wird auch von Antistatika und Farbpigmenten beeinflufßt. Besonders Rot-Pigment wirkt als Stabilisator für Polypropylen, was aus den Ofen-Alterungsversuchen hervorgeht; es verliert diesen Effekt aber bei höheren Temperaturen.
    Notes: The correlation between different methods of measuring thermo-oxidative stability of polypropylene has been studied. The oxidation induction times were measured using differential scanning calorimetry (DSC) in the temperature range from 160°C to 240°C up to 10000 min. The same samples were oven-aged in the temperature range from 130°C to 160°C up to 13000 h.The dynamic experiments performed by DSC show different results for differently stabilized samples. At slow heating rates the results of the dynamic experiments corresponded best to the results of the isothermal experiments.The straight-line Arrhenius plots of the isothermal DSC measurements do not correlate with the straight-line Arrhenius plots of the oven-aging tests. The Arrhenius plots obtained by these two methods either intersect close to the melting temperature of polypropylene or show jumps towards longer times when switching from DSC to oven-aging. It was found that the apparent activation energies obtained from the oven-aging tests are much lower than these obtained by DSC measurements. Almost the same activation energies were obtained for all the samples in oven-aging, while for the differently stabilized samples the activation energies from DSC measurements showed different results.Antistatic additives and colour pigments influence the thermal stability of polypropylene. Especially red pigment acts like a stabilizer for polypropylene, which is noticed at oven-aging testing, but at higher temperatures it loses this stabilizing effect.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...