    ISSN: 1619-7089
    Schlagwort(e): Positron tomography ; Multi ring camera ; Septa removal ; Three dimensional reconstruction
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract An important feature of multi ring positron tomographs is the inter plane septa, the purpose of which is to reduce random and scattered coincidences. In general, such septa also eliminate the coincidence lines of response between pairs of detectors more than one ring apart. The operation of a camera without septa must result in an increase not only in the true coincidence rate, but also in the singles, and therefore in the dead time and randoms rate, and in the scattered coincidences. A configuration option in the coincidence hardware of the 8 ring, 15 slice ECAT 931/08-12 enables a full set of 64 sinograms to be acquired when the septa are removed. The detector normalisation and transmission data for studies with the septa out can be obtained using a rotating pin source. To take maximum advantage of the additional signal, the emission data must be reconstructed using a fully three dimensional reconstruction algorithm. This paper presents an analysis of some phantom studies acquired without septa and reconstructed in three dimensions. The results are compared with data acquired with septa for the same phantoms imaged under similar conditions. It is found that, with the septa removed, the signal to noise for a uniform, 20 cm diameter cylinder improves by a factor of 2.8 in the centre of the field of view, whereas in regions distant from the centre in the axial direction, the signal to noise decreases due to the increase in scatter and randoms. An improvement in signal to noise is observed in 6 cm of the 10 cm axial length of the tomograph.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    European journal of nuclear medicine 15 (1989), S. 736-740 
    ISSN: 1619-7089
    Schlagwort(e): Quality control ; Calibration ; Positron tomography
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract The derivation of physiological parameters in positron tomography relies on accurate calibration of the tomograph. Normally, the calibration relates image pixel count density to the count rate from an external blood counter per unit activity concentration in each device. The quality control of the latter is simple and relies on detector stability assessed by measurement of a standard source of similar geometry to a blood sample. The quality control of the tomographic data depends on (i) detector stability, (ii) uniformity of calibration and normalisation sources and (iii) reproducibility of the attenuation correction procedure. A quality control procedure has been developed for an 8 detector ring (15 transaxial plane) tomograph in which detector response is assessed by acquiring data from retractable transmission ring sources. These are scanned daily and a print out of detector efficiencies is produced as well as changes from a given date. This provides the raw data from which decisions on recalibration or renormalisation are made.
    Materialart: Digitale Medien