Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    European journal of applied physiology 36 (1977), S. 151-169 
    ISSN: 1439-6327
    Schlagwort(e): Physical training in man ; Skeletal muscle enzymes ; Fatty acids ; Glucose ; Morphometry
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary The metabolic and morphologic adaptation to physical training in skeletal muscle tissue of eleven middle-aged, physically untrained men was studied. Muscle biopsies were taken from the vastus lateralis before, after 8 weeks and after 6 months of physical training for analysis of metabolic and morphologic variables. Glucose tolerance test indicated increased insulin sensitivity after 6 months of physical training. The activities of glycogen phosphorylase, hexokinase and glucose-6-P-dehydrogenase were increased but other enzymes involved in glycogen turnover and glycolysis were unchanged after 6 months of physical training. The activities of citrate synthase and cytochrome-c-oxidase, representing the oxidative capacity were significantly increased already after 8 weeks of physical training. The incorporation rate of palmitate-carbon into CO2 and triglycerides increased, and the incorporation rate of leucine-carbon into CO2 decreased with 6 months of physical training. The fiber diameter of both Type 1- and Type 2-fibers increased, while the mitochondrial volume increased predominantly in Type 2-fibers. Significant correlations were found between metabolic, physiologic and morphologic variables before and after physical training. The results indicate an increased oxidative capacity, mainly located to Type 2-fibers, and an increased utilization of fatty acids in response to this type of physical training.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 29 (1991), S. 591-597 
    ISSN: 1741-0444
    Schlagwort(e): Accuracy calculation ; Fluid volume ; Impression force ; Oedema ; Skin model
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract A new instrument for the assessment of oedema based on the impression method is described. The measurement parameters are defined and the errors corresponding to the electrical and mechanical stability of the instrument are measured. The overall accuracy is calculated theoretically for the translocated volume. The accuracy and reproducibility are evaluated on plastic foam. The clinical procedure to measure oedema with this instrument is described. We show that the accuracy of the translocated volume parameter is very dependent on the overall stability of the instrument and that this instrument has an overall relative error of less than 7·3 per cent for a representative measurement. Experimental measurements on plastic foam show that the measurement parameters could be reproduced with standard deviations of less than 6 per cent and that the standard deviations for translocated volume are within the calculated overall relative error. Measurements on four patients with chronic oedema in an extremity show significantly different results on locations where pitting could be recognised compared to the contralateral nonoedematous extremity.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...