Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 89 (2001), S. 7395-7397 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The temperature dependence of magneto-optical property in the visible wavelength region has been studied on four-element semimagnetic semiconductor CdMnCoTe films deposited on quartz glass substrates by using MBE equipment. A large dispersion of Faraday rotation was observed, and the peak of the Faraday rotation was shifted to the higher photon energies with increasing Mn concentration at low temperatures. At 180 K, the value of the Faraday rotation observed for the Cd0.647Mn0.34Co0.013Te film on quartz glass was −0.36 deg/cmG at 630 nm. It is equivalent to the value of −0.36 deg/cmG observed at 77 K for the Cd0.52Mn0.48Te film on quartz glass. At 77 K, the Faraday rotation observed for the Cd0.647Mn0.34Co0.013Te film on quartz glass was −0.49 deg/cmG at 610 nm. The value is approximately two times larger than that of the Cd0.52Mn0.48Te film deposited on the same quartz glass substrate. The origin of the enhancement of Faraday rotation in CdMnCoTe films has been discussed in terms of the magnetic susceptibility χ. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0932
    Keywords: Lumbar spine kinematics ; Dynamic fifting ; Muscle forces ; Disc compression ; Optimization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Epidemiological studies have shown that loads imposed on the human spine during daily living play a significant role in the onset of low back pain. The loads applied to the lumbar spine are shared by a number of structures: muscles; posterior elements, including facets and ligaments; and the disc of a ligamentous motion segment. In vivo, it is not practical to determine forces in these structures using experimental techniques. Biomechanical models, based on an optimization technique or electromyographic activities of the trunk muscles, have been proposed to predict forces in the load transmitting structures. The mathematical models reported in the literature are based on information collected from a wide variety of sources, of which the subject that takes part in the experiment is only one. The present study describes techniques developed in our laboratory to collect from the subjects themselves all the data needed for the formulation of a biomechanical model. The results demonstrated that back lifting with 0 N (no load), 90 N, and 180 N in the hands created maximum external flexion moments respectively of 109.6 Nm, 137.9 Nm, and 161,7 Nm, at the L3–4 disc level. The corresponding external axial compression forces on the disc were 469.5 N, 511.8 N, and 601.5 N. The predicted disc compression varied from 3.4 to 5.0 times the body weight. In comparison to the static lifting mode, the dynamic lifting task caused an increase in the disc compression force ranging from 15.8% to 39.4% depending on the load being lifted (e.g., 3256 N for the dynamic mode vs. 2516 N for the static mode when the subject lifted 90 N). The salient features of the entire protocol developed by the authors and the need for further improvements are also presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...