    Electronic Resource
    Electronic Resource
    Bingley : Emerald
    Journal of quality in maintenance engineering 9 (2003), S. 113-131 
    ISSN: 1355-2511
    Source: Emerald Fulltext Archive Database 1994-2005
    Topics: Technology , Economics
    Notes: Thermal flow sensors with a wide dynamic range are at present not available in spite of the large demand which exists for such sensors in practical fluid flow measurements. In this paper, it is shown that the velocity range of a "time-of-flight" thermal flowmeter for slowly changing flows can be increased by using wires (or other heating/sensing elements) with large thermal inertia (time constant) and heating the sending wire with a continuous sinusoidal current, instead of discrete, very short, square-wave pulses as in the usual pulsed-wire anemometer. The device described here uses two parallel wires of 12.5µm diameter and its usable speed range is 0.05 to 25m/s. Although the present thermal flowmeter can be applied as a point measurement device, the main applications are in pipe flow, especially at very low flow rates. The high sensitivity at low flow rates makes the device especially suitable for this purpose.