Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2991-2995 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A segmented disk electrode is described that produces and controls both relative drift parallel to the magnetic field and localized flow perpendicular to the magnetic field in a Q machine plasma. Measurements of the electron drift velocity vd with respect to the ions, and the electric field E for many bias-voltage combinations are used to demonstrate the controllability of the ratio vE/vd, where vE=E×B/B2, in a narrow channel between the regions that magnetically map to the segments. Radial electric fields of magnitudes ranging from 0 to ±3 V/cm localized within a current channel with parallel electron drift velocities up to half the electron thermal velocity have been produced with the segmented disk electrode.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 1253-1256 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A contamination-free Langmuir probe of novel design is described. Surface contaminants, which lead to erroneous evaluation of plasma parameters by distortion of the probe's current-voltage characteristic, are removed by the indirect heating of the probe tip with separate heating elements running parallel to the probe wire in multibore alumina tubing. This configuration minimizes magnetic field perturbations, while maintaining the compact profile and construction ease of an unheated probe. The design and operating characteristics of such a probe are reported. Temperatures at the probe tip, as measured by a subminiature thermocouple, can exceed 500 °C. Experiments determining the effect of probe temperature, Tprobe, on the characteristic have been performed in a Q-machine plasma (Ti≈Te≈0.2 eV). We find that for Tprobe〈250 °C, the measured electron temperature is up to several times too large, indicating the presence of a contamination layer. This contamination layer is removed for Tprobe ≥300 °C, and accurate electron temperatures are recovered.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 64 (1994), S. 1783-1785 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Ion dynamics in the plasma sheath following the application of a negative voltage pulse to a two-dimensional target are modeled using a time-dependent, two-fluid simulation. The target considered is a square bar of infinite length. We find that the sheath focuses ions near to, but not on, the corner of the bar, resulting in an enhancement of the dose received there.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...