Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 17 (1995), S. 155-160 
    ISSN: 1279-8517
    Keywords: Normal anatomy - Radioanatomy ; Femur ; Total replacement of the hip joint
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé A partir d'une étude prospective portant sur 30 fémurs droits ou gauches prélevés de façon continue au laboratoire d'anatomie, les auteurs étudient les dimensions du canal endosté de l'extrémité supérieure du fémur. Les fémurs sont analysés par 12 coupes scanner, en-dessous du petit trochanter. Les coupes ont été numérisées et les paramètres dimensionnels ont été calculés par l'ordinateur, grâce à un protocole original. Les résultats font l'objet d'une analyse descriptive et d'une analyse corrélative. Sur ces bases dimensionnelles, il apparaît que l'anatomie de l'extrémité supérieure du fémur n'est pas aléatoire ; il existe des canons morphotypiques ; une équation mathématique régit les lois d'un canon normal.
    Notes: Summary Based on a prospective study of 30 right or left femurs removed in a continuous series in the anatomy deparment, a study was made of the dimensions of the endosteal canal of the upper end of the femur. The femora were analysed by means of 12 CT scans below the lesser trochanter. The sections were numbered and the dimensional parameters calaculated by computer, using an original plan. The results were subjected to descriptive and correlative analysis. From these dimensional findings it appeared that the anatomy of the upper end of the femur is not random; morphotypic models exist and the laws of a normal model are regulated by a mathematical equation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1997), S. 283-286 
    ISSN: 1279-8517
    Keywords: Normal anatomy ; Radioanatomy ; Thigh bone ; Total hip arthroplasty
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Il existe au sein de la population une grande variabilité dans l'anatomie du canal endosté de l'extrémité proximale du fémur. Cette variation de l'anatomie pourrait compromettre le résultat de l'arthroplastie totale de hanche lorsque le chirurgien utilise une tige fémorale sans ciment. En effet, si la fixation secondaire d'un implant reste sous la dépendance de nombreux paramètres, il faut avant toute chose obtenir une excellente stabilité primaire, obtenue par l'adéquation morphologique os-implant. Les auteurs se proposent de définir les indications des prothèses fémorales sans ciment, en matière d'arthroplastie totale de hanche, en définissant deux paramètres radio-anatomiques : l'Index Cortico-Médullaire et l'Index d'Evasement Fémoral.
    Notes: Summary There is within the population a considerable variation in the endosteal canal anatomy of the proximal extremity of the femur. This anatomical variation might jeopardize the result of the total hip arthroplasty when the surgeon uses a cementless femoral shaft. Inded, if the secondary fixation of an implant stays under the dependency of many parameters, one has to obtain before anything else a very good primary stability, obtained by the morphological appropriateness of the bone-implant. The authors propose to define the cementless indications, as regards total hip arthroplasty, defining two radio-anatomical parameters: the Cortico-Medullary Index and the Femoral Flare Index.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1998), S. 283-286 
    ISSN: 1279-8517
    Keywords: Normal anatomy ; Radio-anatomy ; Thigh bone ; Total hip arthroplasty
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract There is within the population a considerable variation in the endosteal canal anatomy of the proximal extremity of the femur. This anatomical variation might jeopardize the result of the total hip arthroplasty when the surgeon uses a cementless femoral shaft. Inded, if the secondary fixation of an implant stays under the dependency of many parameters, one has to obtain before anything else a very good primary stability, obtained by the morphological appropriateness of the bone-implant. The authors propose to define the cementless indications, as regards total hip arthroplasty, defining two radio-anatomical parameters: the Cortico-Medullary Index and the Femoral Flare Index.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1998), S. 299-302 
    ISSN: 1279-8517
    Keywords: Talocrural joint ; Ankle arthroplasty
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Based on two orthogonal radiologic views, the authors present a morphometric study of the talocrural joint. In 50 normal subjects, 10 parameters were measured and divided into 3 groups: the distal tibial joint surface parameters, the malleolar parameters and the talar parameters. These parameters were treated in both a descriptive and a correlative analysis. If the talocrural joint is a hinge joint whose talar articular surface can be simplified and classed as a cylinder segment, it is possible to calculate its curve radius. Then the correlative analysis allows to define the talar parameters and the corresponding parameters of the distal tibial joint surface. The malleolar parameters are independent factors. This study is the first morphologic analysis to serve as a basis for an ankle arthroplasty.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 6 (1984), S. 215-223 
    ISSN: 1279-8517
    Keywords: Functional anatomy ; Knee ; Musculus semimembranosus
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé La dissection de 18 genoux de cadavres frais permet de préciser la terminaison distale du muscle semi-membranosus. Elle est exclusivement tibiale par trois tendons qui rendent ce muscle fonctionnel quelle que soit la position du genou. Les autres faisceaux parfois décrits ne sont que des expansions aux formations ménisco-tibiale et ménisco-fémorale dont il faut dissocier cette terminaison distale. Une étude électromyographique, réalisée chez 17 sujets confirme que ce muscle est plus un frein de la rotation externe qu'un rotateur interne, d'autant plus que la hanche est en flexion et le genou en extension.
    Notes: Summary The dissection of 18 knees taken from fresh cadavers has led to a detailed description of the semimembranosus muscle (musculus semimembranosus). It is exclusively tibial with its three tendons rendering the muscle functional, whatever the position of the knee may be. There are other attachments, sometimes described are merely expansions extending to the meniscotibial and menisco-femoral formations, from which this distal termination must be distinguished. Electromyography performed on 17 specimens confirms that this muscle serves more as a brake on outer rotation than an inner rotator muscle, especially when the hip is flexed and the knee stretched.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1997), S. 299-302 
    ISSN: 1279-8517
    Keywords: Talocrural joint ; Ankle arthroplasty
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé A partir de deux incidences radiologiques orthogonales, les auteurs proposent une étude morphométrique de l'art. talo-crurale. Sur une population de 50 sujets non pathologiques, dix paramètres ont été mesurés et répartis en trois groupes : le groupe des paramètres de la surface articulaire distale du tibia, le groupe des paramètres malléolaires, le groupe des paramètre du talus. Ces paramètres ont fait l'objet d'une analyse descriptive et d'une analyse corrélative. Si l'art. talo-crurale est une ginglyme dont la surface articulaire du talus peut être simplifiée et assimilée à un segment de cylindre, les auteurs, par le calcul, peuvent en définir le rayon de courbure. L'analyse corrélative permet alors de définir les paramètres du talus et les paramètres correspondant de la surface articulaire distale du tibia. Les paramètres malléolaires en restent indépendants. Ce travail est une première analyse morphologique pour concevoir une arthroplastie de cheville.
    Notes: Summary Based on two orthogonal radiologic views, the authors present a morphometric study of the talocrural joint. In 50 normal subjects, 10 parameters were measured and divided into 3 groups: the distal tibial joint surface parameters, the malleolar parameters and the talar parameters. These parameters were treated in both a descriptive and a correlative analysis. If the talocrural joint is a hinge joint whose talar articular surface can be simplified and classed as a cylinder segment, it is possible to calculate its curve radius. Then the correlative analysis allows to define the talar parameters and the corresponding parameters of the distal tibial joint surface. The malleolar parameters are independent factors. This study is the first morphologic analysis to serve as a basis for an ankle arthroplasty.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1997), S. 85-90 
    ISSN: 1279-8517
    Keywords: Anatomy ; Hip ; Iliac artery ; Arthroplasty ; Vascular complication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Most direct vascular trauma occurring during hip surgery results from injury to pelvic vascular structures which are not visible during the procedures of reaming, drilling holes or the fixation of screws. In this study, 5 pelves of fresh cadavers were injected with a radiopaque mixture and were visualised with a scanner according to 5 predetermined sections. Bone depth of the acetabulum was measured in each section. A calculation was made describing the minimal distance separating the inner cortex from the principal pelvic vessels. After an anatomic dissection of each pelvis, the relationship between the vessels and screws of the fixation cup, implanted identically on the quadranted acetabulum, was observed. The screws placed in the anterior and inferior quadrants and the center of the acetabulum endangered the external iliac v. and a. and the obturator pedicle. The depth of the periacetabular bone was greater in the superior and posterior quadrants. The inferior gluteal, pudendal and superior gluteal aa. were more than ten mm from the posterior wall. Conversely, the external iliac and obturator pedicles came in contact with the osseous surface on which they lay. A projection of the vessels on the acetabulum was made, and the reproducible character of the acetabular-quadrant system was verified. The superior quadrant offers all the characteristics of a vascular safe zone. A knowledge of these anatomic relationships explain vascular trauma in pelvic fractures and helps to prevent vascular injury in hip surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 6 (1984), S. 19-22 
    ISSN: 1279-8517
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Conclusion La dissection anatomique permet de dissocier la terminaison distale du muscle demi-membraneux des formations méniscocapsulo-ligamentaires postero-internes. Trois tendons terminaux résistants sont individualisés, mais leur terminaison est uniquement tibiale. Les expansions capsulaires issues de sa gaine restent indépendantes de ces trois tendons. Le muscle demi-membraneux, fléchisseur du genou, extenseur de la hanche, et freinateur de l'extension de jambe sur la cuisse possède une action rotatrice interne limitée lorsque la hanche est étendue. Cette action de rotation interne n'est pas comparable avec celle de rotation externe du muscle biceps femoris caput breve et parler de ≪ biceps interne ≫ est impropre. En revanche, son action de frein de la rotation externe est mise en évidence par l'intensité de l'activité électrique enregistrée pendant ce mouvement. Elle apparaît d'autant plus importante que le muscle est mis en tension par la flexion de la hanche et l'extension du genou.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1997), S. 13-16 
    ISSN: 1279-8517
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Conclusion La méthode de prévention irremplaçable des accidents vasculaires iatrogéniques, survenant lors d'une chirurgie de hanche, reste le bilan vasculaire préopératoire. En cours d'intervention, certaines mesures chirurgicales doivent être suivies, notamment si les repères osseux sont modifiés. L'aide du quadrillage acétabulaire permet de positionner en toute sécurité les vis de fixation, en évitant les quadrants antérieurs et la zone centrale de l'acétabulum. Le forage des trous ou des plots d'ancrage doit se faire selon une direction perpendiculaire à la surface semi-lunaire afin de guider la mèche en territoire connu. Il convient, par ailleurs, de ne pas trop dépasser le plan de la corticale interne lors du forage, et d'implanter des vis dont la longueur ne dépasse pas de 10 mm l'épaisseur osseuse mesurée, au risque de menacer des structures vasculaires majeures même dans les quadrants postérieurs. Il faut par ailleurs souligner que le respect de la corticale interne est tout aussi important lors du scellement d'une cupule, la présence de ciment dans le petit bassin pouvant avoir les mêmes conséquences délétères sur les vaisseaux. Ainsi la connaissance des trajets vasculaires et de leur projection sur l'acétabulum permet une implantation en toute sécurité des implants acétabulaires lors des arthroplasties totales de hanche. Enfin, elle explique parfaitement la corrélation que l'on trouve dans les fractures du bassin, entre l'importance des lésions osseuses et les lésions vasculaires tronculaires observées.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Surgical and radiologic anatomy 19 (1997), S. 85-90 
    ISSN: 1279-8517
    Keywords: Anatomy ; Hip ; Iliac artery ; Arthroplasty ; Vascular complication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Résumé Les traumatismes vasculaires directs survenant au cours de la chirurgie de hanche découlent pour la plupart du fraisage, du forage d'un trou ou de la pose d'une vis d'ancrage. Ces gestes se font à l'aveugle vis-à-vis des vaisseaux pelviens. Cinq pelvis injectés étaient étudiés au scanner suivant 5 plans de coupe. Nous avons mesuré les épaisseurs osseuses des acétabulums, ainsi que la distance qui séparait la corticale interne des principaux vaisseaux pelviens. Après dissection de chaque pelvis, nous avons noté les relations qui existaient entre les vaisseaux et des vis de fixation de cupule implantées de manière identique dans les acétabulums quadrillés. Les vis des quadrants antérieurs, inférieurs et du centre de l'acétabulum, mettaient en danger la v. et l'a. iliaques externes, le pédicule obturateur. L'épaisseur de l'os périacétabulaire était la plus importante dans les quadrants supérieur et postérieur. Les aa. glutéale inférieure, pudendale et glutéale supérieure restaient éloignées de plus de 10 mm de la paroi postérieure. A l'inverse, les pédicules iliaque externe et obturateur entraient en contact avec la surface osseuse sur laquelle ils étaient fixés. Nous avons établi une projection des vaisseaux sur l'acétabulum et vérifié le caractère reproductible du quadrillage acétabulaire. Le quadrant supérieur offre toutes les caractéristiques d'une zone de sécurité vasculaire. La connaissance de ces rapports anatomiques explique les lésions vasculaires associées aux traumatismes du bassin et participe à la prévention des accidents vasculaires au cours de la chirurgie de hanche
    Notes: Summary Most direct vascular trauma occurring during hip surgery results from injury to pelvic vascular structures which are not visible during the procedures of reaming, drilling holes or the fixation of screws. In this study, 5 pelves of fresh cadavers were injected with a radiopaque mixture and were visualised with a scanner according to 5 predetermined sections. Bone depth of the acetabulum was measured in each section. A calculation was made describing the minimal distance separating the inner cortex from the principal pelvic vessels. After an anatomic dissection of each pelvis, the relationship between the vessels and screws of the fixation cup, implanted identically on the quadranted acetabulum, was observed. The screws placed in the anterior and inferior quadrants and the center of the acetabulum endangered the external iliac v. and a. and the obturator pedicle. The depth of the periacetabular bone was greater in the superior and posterior quadrants. The inferior gluteal, pudendal and superior gluteal aa. were more than ten mm from the posterior wall. Conversely, the external iliac and obturator pedicles came in contact with the osseous surface on which they lay. A projection of the vessels on the acetabulum was made, and the reproducible character of the acetabular-quadrant system was verified. The superior quadrant offers all the characteristics of a vascular safe zone. A knowledge of these anatomic relationships explain vascular trauma in pelvic fractures and helps to prevent vascular injury in hip surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...