Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: DEHARO, J.-C., et al .: DDDR Pacing Driven by Contractility Versus DDI Pacing in Vasovagal Syncope: A Multicenter, Randomized Study. Recent clinical trials have shown that selected patients with recurrent vasovagal syncope (VVS) may benefit from permanent cardiac pacing. In a previous study using head-up tilt testing (HUT) the authors demonstrated that the increase in sympathetic activity preceding syncope could be sensed by a microaccelerometer located in the tip of a ventricular pacing lead and used to drive a rate adaptive pacer. They compared in a single blind randomized crossover study, DDDR pacing driven by this system, with conventional DDI pacing in patients with recurrent VVS. Twenty-three patients (age 61.8 ± 15.2  years , 19 men) with recurrent VVS were enrolled at seven European centers and underwent implantation of a “MiniLivingD/Best” pacing system. Inclusion criteria were (1) 〉6 cumulative syncopal episodes or ≥1 syncope within 6 months of a positive HUT, and (2) a positive HUT with bradycardia. Using a crossover study design, the pacemakers were randomly programmed for two successive periods of 6 months to DDDR or DDI mode. The numbers of episodes of syncope and presyncope, and quality-of-life (QOL), were assessed at the end of each period. During the 6 months before implant, the mean number of syncopal episodes per patient was 3.2 ± 9 . During pacing in the DDDR mode, 0.09 ± 0.29 syncope/presyncope per patient was observed, while during the DDI period 0.48 ± 0.73 episodes per patient were reported (P 〈 0.05) . QOL scores were77.40 ± 11.32in the DDDR mode versus74.45 ± 14.59in the DDI mode (NS). In patients with recurrent VVS, symptomatic recurrences were less frequent during contractility-driven DDDR pacing, than during DDI pacing. QOL was similar in the two pacing modes. (PACE 2003; 26[Pt. II]:447–450)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...