Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0614
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Abstract A disposable-type microbial sensor was developed for the determination of both the biochemical oxygen demand for nitrification (N-BOD) and inhibiting effects on nitrifying bacteria. The sensor was based on the respiratory activity of nitrifying bacteria immobilized on a miniature oxygen electrode. Typical response times for measuring N-BOD of ammonium standard solutions as well as of wastewater samples were in the range of 6–12 min. A dynamic evaluation of the signals after a measuring time of 120 s also resulted in good reproducibility and sensitivity. A daily profile of a municipal sewage plant was recorded, comparing the biosensor data with two standard methods. For the measurement of nitrification-inhibiting effects a 120-s dynamic signal evaluation was preferred to a steady-state method because of the long recovery times resulting from extended exposure to inhibitors. However, steady-state measurement techniques allowed allylthiourea detection with a ten times higher sensitivity. Because of the advantages of this miniaturized electrode, e.g. short response time, simple measuring procedure and low costs of production, this sensor system is considered to be suitable for commercial application in environmental analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' journal of analytical chemistry 364 (1999), S. 584-589 
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract A sensitive dipstick assay for 2,4-dichlorophenoxyacetic acid (2,4-D) detection was developed. The assay was based on the competitive reaction of 2,4-D and enzyme tracer with monoclonal antibodies immobilised on an Ultrabind® membrane. The binding of enzyme tracer on the test strip was determined by a simple, portable reflectometer as remission at 657 nm. Using this technique, 2,4-D could be detected in a concentration range of 0.5 μg/L to 100 μg/L. The center point of the 2,4-D test was found at a concentration of 6 μg/L. Cross-reactivity with 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) as determined by this dipstick assay was 2.5% and 3% by standard ELISA technique using microtiter plates. The assay was applied in the detection of 2,4-D in real water samples, and sensitivity was comparable to spiked water samples. If combined with an effective extraction procedure that results in recovery rates of 90%, the dipstick assay can be used to monitor human exposure to 2,4-D from contamination in water, from oranges and in testing urine samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...