Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Amsterdam : Elsevier
    Journal of Ultrasructure Research 10 (1964), S. 189-193 
    ISSN: 0022-5320
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Biologie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 67 (2000), S. 291-296 
    ISSN: 1432-0827
    Schlagwort(e): Key words: Densitometry — X-ray — Bones — Osteoporosis — Body composition
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Abstract. We compared the bone and body composition results in vivo on two bone densitometers using fan-beam geometry (EXPERT and PRODIGY) with those using pencil-beam geometry (DPX). Measurements were made on large groups of adults ranging in weight from about 50 to 120 kg. Both spine and femur neck BMD on the fan-beam densitometers averaged within 1% of the pencil-beam results, and there was no magnitude dependence of the results by Bland-Altman analysis. Total body BMC and BMD on the PRODIGY and DPX were congruent, but on the EXPERT, BMC was about 2% lower and BMD 2% higher than corresponding values on the DPX. Soft-tissue composition was closely congruent for the PRODIGY and DPX; the comparable EXPERT-DPX differences showed greater scatter but no significant magnitude dependence. The smaller fan-angle of the PRODIGY (4°) probably contributed to its better congruence to pencil-beam results compared with the EXPERT (12°).
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 56 (1995), S. 201-205 
    ISSN: 1432-0827
    Schlagwort(e): Bone densitometry ; Bone ; Osteoporosis ; Aging osteopenia
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Abstract Bone mineral density (BMD) was measured in 353 healthy white women using dual-energy X-ray absorptiometry (DXA). Measurements were made of both the posterior-anterior (PA) and lateral spine, as well as the proximal femur (neck and Ward's triangle). From age 50 to 80 years, the BMD of the PA spine and femur neck BMD had an 18% diminution (0.6%/year), and BMD of the lateral spine showed about a 35–40% decline (1.4%/year). The Ward's triangle region of the femur was not quite as decreased (30% or 1.1%/year). The BMD decrease associated with aging did not differ as much among sites when expressed relative to the intrapopulation variation rather than as a percentage. The Z-score for PA spine and femur neck BMD (-1.1) was significantly different than that for lateral spine BMD (-1.6); Ward's triangle was intermediate (-1.3), i.e., the lateral spine still showed the highest sensitivity to aging. However, the ability to detect age changes in an individual subject can be increased only if the precision error for lateral spine BMD is not increased to a greater extent than the sensitivity.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Calcified tissue international 65 (1999), S. 91-99 
    ISSN: 1432-0827
    Schlagwort(e): Key words: Bone densitometry — Osteoporosis — Axial skeleton — Bone.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin , Physik
    Notizen: Abstract. We measured bone mineral density (BMD in g/cm2) of the spine (L2-L4) and femur (four regions) in 1472 and 1487 cases, respectively, of ambulatory white women ages 20–79 years in the USA. A DPX densitometer was used in a mobile setting. The BMD values for women up to 69 years corresponded closely with published values for the USA, the UK, and northern Europe; our values were somewhat lower than those from other studies only in women over 70 years. The USA data were combined with data from Europe to give reference curves on about 12,000 subjects. Decreases of BMD with age in women below 50 years were much smaller than in older women (0.2% versus 0.6–1.0% per year). Femoral bone decreased from the neck region, but not the trochanter with age; the decrease of total femur BMD with age was due to loss from the former region. Loss of bone mineral content (BMC in g) from the femur neck and total femur region did not accelerate until after age 50 years, much like the spine. The apparent decrease of BMD in these regions that begins about age 40 actually is due to an increase of bone area. About 20% of USA women aged 50–79 years had BMD levels for the lumbar spine, or for the femur neck, more than −2.5 SD below the average values in young adult women 20–39 years old. Body weight had several times more impact on BMD than height, and in fact, a change of 1 kg in postmenopausal women was commensurate with the effect of a 1-year change in age. Subjects in the lowest quartile of body weight had T-scores that were 1 SD below those in the highest quartile.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Histochemistry and cell biology 78 (1983), S. 41-52 
    ISSN: 1432-119X
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Medizin
    Notizen: Summary A histochemical analysis involving tinctorial and solubility tests was pursued in conjunction with electron microscopy for the purpose of identifying the dark brown epidermal pigment of a barnacle (Balanus eburneus) as melanin and/or ommochrome. Histochemically, comparisons were made with other brown pigments located in the subcarapal epidermis of another crustacean, the fiddler crab (Uca pugilator), the dorsal skin of the red-backed salamander (Plethodon cinereus), the liver and testis of a slider turtle (Chrysemys sp.) and the substantia nigra of human brain. The solubility properties of the pigment of the two crustacean invertebrates were in general similar to one another and markedly different from the pigment of the three vertebrates. Insolubility in appropriate solvents classified the vertebrate pigment as melanin. The invertebrate pigment, however, which was soluble in the ommochrome solvents, concentrated sulfuric and formic acids and 2-chloroethanol, remained insoluble in the ommochrome solvents, dilute aqueous and methanolic hydrochloric acid and dilute sulfuric acid. On the basis of these solubilities, an unequivocal classification of the invertebrate pigment as either melanin or ommochrome did not appear possible. The tinctorial and electron microscopic properties of the barnacle pigment were also equally ambiguous in regard to its specific classification.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Annals of biomedical engineering 17 (1989), S. 177-181 
    ISSN: 1573-9686
    Schlagwort(e): Bone ; Densitometry ; Osteoporosis ; Fracture ; Skeleton
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin , Technik allgemein
    Notizen: Abstract Several noninvasive measurement methods are used for evaluation of metabolic disease. Single-photon (125I) scans of the peripheral skeleton are useful in some diseases but are ineffective in osteoporosis (even on the distal radius or os calcis) because they cannot predict spinal or femoral density. Also, peripheral measurements show high percentages of false negatives, that is many patients with fractures have normal peripheral density. Dual-photon (153Gd) scans of the spine, femur, and total skeleton are precise and accurate (2% error) and provide direct measurements of bone strength at fracture sites. This gives the best discrimination of abnormality and the most sensitive monitoring. Quantitative computed computed tomography (QCT) allows measurement of the spine but not the critical proximal femur area. QCT has a large accuracy error because (a) the limited are measured (under 5 cm3) fails to represent the total vertebral body, (b) technical errors and (c) variable fat and osteoid influence the results.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...