Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 107 (1997), S. 2798-2806 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Reactions of laser-ablated Cr atoms with O2 gave a very strong, sharp 965.4 cm−1 band and weak, sharp 1869.7, 984.3, 914.4, 846.3, 716.2, and 643.1 cm−1 bands. The 1869.7, 965.4, and 914.4 cm−1 bands track together on annealing, show 52Cr, 53Cr, 54Cr isotopic splittings appropriate for a single Cr atom and triplets with statistical 16,18O2 for two equivalent O atoms, and are assigned to the ν1+ν3, ν3 and ν1 modes of the bent (128°±4°) chromium dioxide OCrO molecule. The 984.3 cm−1 band shows chromium isotopic splittings for two Cr atoms and 16,18O2 components for two O atoms, and is attributed to the bent CrOCrO molecule. The weak 846.3 cm−1 band exhibits proper oxygen isotopic behavior for CrO and is redshifted 39 cm−1 from the gas-phase value, the maximum shift observed for a first row transition metal monoxide. The sharp 716.2 and 643.1 cm−1 bands track together; the former reveals Cr isotopic splittings for two Cr atoms and the latter 16,18O2 splittings for two sets of dioxygen subunits; the branched-puckered-ring dimer O(Cr2O2)O is identified. Annealing produces new bands due to CrOO, CrO3, Cr(OO)2 and the ring dimers (Cr2O2) and (Cr2O2)O, which are identified from isotopic shifts and splitting patterns. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4994
    Keywords: Monochromator ; calibration ; mercury ; argon ; near-infrared
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The emission spectra of four mercury vapor lamps are used to obtain wavelength calibration curves for the double-grating emission monochromator of a spectrofluorimeter. The use of second- and third-order diffraction lines and emission lines from the argon carrier gas provides a rich spectrum, which extends well into the near-infrared spectral region and produces an improved calibration curve. More than 60 emission lines are listed between 250 and 900 nm, which is sufficient to produce an extremely accurate monochromator calibration. Additional second- and third-order lines can be used to even longer wavelengths (〉1200 nm). The effectiveness of three scattering surfaces is compared.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...