Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    Bloomington, Ill. : Periodicals Archive Online (PAO)
    Journal of Educational Research. 42:7 (1949:Mar.) 547 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 13 (1973), S. 11-18 
    ISSN: 1432-0827
    Keywords: Bone ; Bending ; Measurements
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Description / Table of Contents: Résumé La courbure des tibias de chiens et de lapins a été étudiéein vivo. Une nouvelle méthode physique (avec une marge d'erreur inférieure à 1%) donne des valeurs de stabilité osseuse aisément reproductibles. Les résultats de rigidité de courbure, mesuréein vivo etin vitro, sont trés voisins lorsque les extrémités sont minces. Lorsqu'elles sont épaisses, des tissus mous sont présents dans la région à tester et différentes valeers de charges suivent la même courbure. Une formule pour compenser l'effet des tissus mous (peau, muscles et tendons) est proposée. La rigidité vraie de courbure est déterminée à l'aide des valeursin vivo sans devoir mesurer par la suite l'os mis à nu. La comparaison des mesures montrent que les valeurs obtenues à l'aide de la formule traduisent la rigidité vraie de courbure avec une marge d'erreurs de 0,3 à 10,5%. Une charge de 4700±719 g donne une rigidité vraie de courbure de 0,1 mm, d'une surface osseuse de 1,0 cm2.
    Abstract: Zusammenfassung Die Beugung von Hunde- und Kaninchen-Tibias wurdein vivo untersucht. Eine neue einfache physikalische Methode (Fehlergrenze weniger als 1%), welche reproduzierbare Werte der Knochenstabilität vermittelt, wurde dabei angewandt. Die Resultate der Beugungs-Steifheit, welchein vivo undin vitro gemessen wurde, zeigten nur dann fast identische Werte, wenn die Extremitäten dünn waren. Sobald dicke, weiche Stellen im gemessenen Bereich vorhanden waren, erfolgten bei der gleichen Beugung unterschiedliche Belastungswerte. Es wird eine Formel vorgeschlagen, die den Einfluß der weichen Stellen (Haut, Muskeln und Sehnen) korrigieren soll. Die richtige Beugungs-Steifheit wurde mit Hilfe derin vivo-Werte bestimmt, ohne daß nachher der freigelegte Knochen gemessen werden mußte. Vergleichende Messungen zeigten, daß die mit dieser Formel gefundenen Werte die richtige Beugungs-Steifheit mit einer Fehlergrenze zwischen 0,3 und 10,5% wiedergaben. Eine Belastung von 4700±710 g ergab die korrekte Beugungs-Steifheit von 0,1 mm in einem Knochenbereich von 1,0 cm2.
    Notes: Abstract The bending of the tibiae of dogs and rabbitsin vivo was studied. A new physical method (margin of errors less than 1%) which gives readily reproducible values of bone stability is reported. The results of bending stiffness, measuredin vivo andin vitro, were nearly identical only if the extremities were slim. If thick, soft parts in the measuring area were present, different loading values followed the same bending. A formula to correct the influence of the soft parts (skin, muscles and tendons) was proposed. The true bending stiffness was determined with the aid of thein vivo values without having to measure the exposed bone afterwards. Comparisons of measurements showed that the values found with the formula reflected the true bending stiffness in a range of errors between 0.3 and 10.5%. A load of 4700±710 g gave a true bending stiffness of 0.1 mm and of a bone area of 1.0 cm2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Langenbeck's archives of surgery 329 (1971), S. 1016-1016 
    ISSN: 1435-2451
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Research in experimental medicine 157 (1972), S. 218-220 
    ISSN: 1433-8580
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Research in experimental medicine 172 (1978), S. 181-185 
    ISSN: 1433-8580
    Keywords: Bone elasticity ; In vivo study ; Human os radii ; Knochenelastizität ; In vivo-Studie ; Menschliches os radii
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird eine neue Meßmethode zur in vivo-Bestimmung des Elastizitätsmoduls am menschlichen os radii beschrieben. Der Gerätefehler hat einen Variationskoeffizienten von ± 1,86%. Der Reproduzierbarkeit der Messungen am gesunden Menschen liegt ein Variationskoeffizient von ca. 10% zugrunde. Unsere Untersuchungen an 124 Armen von gesunden Menschen, nach Alter, Geschlecht und Seite aufgeschlüsselt, ergaben einen statistisch signifikanten höheren E-Modul bei über 60jährigen gegenüber 11- bis 14jährigen Knaben. Ein Geschlechts- und Seitenunterschied konnte statistisch nicht abgesichert werden.
    Notes: Summary This is a report of a new method for in vivo determination of the Young modulus of human os radii. The failure of the apparatus is ± 1.86 per cent. The accuracy of the measuring procedure on healthy subjects bases on a variation coefficient of nearly 10 per cent. 124 forearms of healthy persons had been studied in relation to age, sex and to the right and the left os radii. There was a statistically significant higher elastic property of the bones of adolescent versus elder men (over 60 years), but no significant differences between male and female. Right and left os radii had nearly the same amounts for the Young modulus.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...