ISSN:
0935-6304
Keywords:
Thin Layer Chromatography, HPTLC
;
Qualitative evaluation
;
Precise Rf determination by U-chamber, technique, ±1%
;
Comparison of calculated and measured values
;
Chemistry
;
Analytical Chemistry and Spectroscopy
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
Notes:
Correlation between chemical structure and Rf-values was studied in the case of aniline and its derivatives using high performance TLC and a U-chamber. The characteristic group constants referring to each substituent were determined by chromatographing derivatives with one substituent and aniline in toluene and dibutyl ether respectively. On the basis of these constants the RM and Rf values of derivatives with more substituents were calculated. Comparing the calculated and measured values good agreement was found.
Additional Material:
2 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/jhrc.1240010308