Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 17 (1994), S. 851-858 
    ISSN: 0935-6304
    Keywords: High resolution gas chromatography ; Chlorinated hydrocarbons ; Polychlorinated biphenyls ; PCB indicator congeners ; Coelution ; Toxic PCB congeners ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Eighty one polychlorinated biphenyls (PCBs) and nineteen chlorinated pesticide standards have been analyzed on a newly developed apolar high resolution gas chromatography (HRGC) column. Emphasis was placed on the determination of PCB indicator congeners which are part of national regulations, and of toxic coplanar PCB congeners.The new column enables almost unambiguous quantification of the PCB indicator congeners (PCB 138 can be separated from both PCB 163 and PCB 164; PCB 28 and PCB 31 were also separated and no coelution was observed for PCB 52, PCB 118, and PCB 180). The new column furnished better results than CP-Sil 8 for the analysis of PCB indicator congeners in a sample of seal blubber.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 403-412 
    ISSN: 0935-6304
    Keywords: High resolution GC ; Apolar phase ; Alkanes ; Napthenes ; Aromatics ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper deals with the separation of alkanes, naphthenes, and aromatic compounds in naphtha and reformate, on a newly developed apolar high resolution GC column. The selectivity of this apolar phase has been compared with those of squalane, DB-1, and SE-30. A total of 95 hydrocarbons were reliably identified, mostly by GC-MS. Repeated measurements of Kováts retention indices are presented as evidence for the reproducible manufacture of fused silica columns coated with this phase.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...