    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 12 (2001), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: For several radiological examinations, a clinician can select between conventional and spiral computed tomography. Using both techniques, this study aimed at evaluating the difference in absorbed doses when examining a single lateral jaw segment in a human cadaver head and Rando phantom. The present study involved the placement of thermoluminescent dosimeter (TLD) chips (GR-200) in the thyroid gland, and bilaterally, in the parotid and submandibular glands and the lenses of the eyes in both a human cadaver and a Rando phantom at corresponding locations. Consecutive conventional spiral tomographic examinations were carried out in both the left upper and lower premolar area, using a Cranex TOME® multifunctional unit. Each examination consisted of 4 slices with a 2 mm slice thickness and exposure parameters of 57 kV, 56 seconds and 1.6–2.0 mA. Regarding spiral computed tomography (CT), a Somatom Plus S® scanner (Siemens, Erlangen, Germany), with a slice thickness of 1 mm with settings at 120 kV and 165 mA, was used on both phantoms and separately in the upper and lower jaw. With conventional tomography, the findings of the present study showed that the parotid and submandibular glands on the side near the X-ray tube received the highest dose, both for the cadaver head (doses ranging from 0.5 to 1.3 mGy) and the phantom (doses ranging from 0.6 to 2.6 mGy). For CT of the upper jaw, the highest doses were delivered to the parotid glands with an average absorbed dose of 9.2 and 10.6 mGy for the cadaver head and phantom, respectively. The submandibular glands received the highest doses during CT examination of the lower jaw with an average of 7.8 and 12.9 mGy for the cadaver head and phantom, respectively. It appears from the present investigation that if small edentulous regions are examined, radiation doses during conventional tomography remain much lower than during CT imaging. However, when multiple tomographic cuts are required, a spiral CT examination can replace a series of conventional examinations, especially in cases such as the rehabilitation of an edentulous upper jaw or a more complex surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1436-3771
    Keywords: Key words Dental radiography ; Digital dental radiography ; Panoramic radiography ; Diagnostic imaging ; Radiographic image enhancement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  One of the main advantages of digital imaging is the possibility of altering display options for improved image interpretation. The aim of the present study was to evaluate the subjective image quality of direct digital panoramic images and compare the results with those obtained from conventional images. Furthermore, the effect of various filter settings on image interpretation was assessed. Panoramic images were obtained with three different types of panoramic equipment (one direct digital and two conventional units) from three groups of 54 patients with a natural dentition in all quadrants. The first series of panoramic images consisted of 54 unprocessed digital images; conventional film images (n=108) comprised the second and third series. A final series consisted of the digital images treated with three different filters (”smoothening,””sharpening,” and ”contrast enhancement”). All images were scored randomly by four experts in oral radiology on a 4-point rating scale. The results showed a statistically significant difference in scorings between the conventional and digital panoramic units. The main reason for poor image quality appeared to be a combination of blurring and overlapping in the panoramic image. The premolar region in the upper jaw was the region where most additional radiographs were needed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...