Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Key words Hemifacial spasm ; Magnetic resonance imaging ; Magnetic resonance angiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract MRI was used to investigate 100 patients with hemifacial spasm, using 3D-FT T2-weighted (CISS) and contrast-enhanced 3D-FT T1-weighted (turbo-FLASH) sequences in all cases. MR angiography was performed in 54 patients, using 3D-MT FISP images. Decompression of the facial nerve through a retromastoid craniotomy was performed in all patients. Hemifacial spasm caused by tumours in the cerebellopontine angle was not included. Vascular contact with the facial nerve root-exit zone or at the internal auditory canal was present in 96 of 100 patients with hemifacial spasm. The vessel responsible was the vertebral artery (VA) in 18 cases, the posterior inferior cerebellar artery (PICA) in 23, the anterior inferior cerebellar artery (AICA) in 22, the VA and PICA in 24, VA and AICA in 3, PICA and AICA in 1, VA, PICA and AICA in 4, and a vein in 1 case. CISS images showed compressive vascular loops better than contrast-enhanced turbo-FLASH images alone. The sensitivity of MRI was high, since only one false-negative case was found among the 100 patients who underwent surgery.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 1 (1998), S. 255-258 
    ISSN: 1434-6079
    Keywords: PACS. 32.80.Pj Optical cooling of atoms; trapping
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: We have developed an iron-core electromagnet and used it to trap neutral atoms. The magnetic field can be switched from a spherical quadrupole configuration to a Ioffe configuration within 2 ms. We load 2 87Rb atoms from a vapor into a Magneto-Optical Trap (MOT) and transfer them into the purely magnetic trap with an efficiency of 95%. A strong radial compression is possible since we can generate quadrupole gradients up to 0.1 T/cm with an excitation current of 10 A (400 W of power consumption).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...