Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2242
    Keywords: Key words Wheat ; Maize ; Doubled haploid ; Anther culture
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract  Anther culture and maize hybridization are two frequently used techniques for doubled haploid production in wheat (Triticum aestivum L.). Information on the field performance of lines derived from these techniques is limited. This study was conducted to compare the performance of F4:6 lines obtained by single-seed descent with lines obtained by anther culture and maize (Zea mays L.) pollination from the same cross of spring wheat, ’Chris’/MN 7529. Thirty-three lines derived from each of those techniques were evaluated in six environments for grain yield, protein content, test weight, heading date, kernel weight and plant height. Mean performance of the single-seed descent lines exceeded performance of the anther culture lines for grain yield, kernel weight and plant height with no apparent differences for grain protein content, test weight and heading date. No differences between trait means for the single-seed descent and maize pollination lines were found except for plant height. The best 5 lines from each method for grain yield, protein content and test weight were similar in performance except that the protein content was higher for the maize pollination lines than for the single-seed descent lines. Acceptable levels of agronomic performance could be found among lines from each method. Wide acceptance of the doubled haploid technique for pure line production in breeding programs may, however, be limited by the often poor efficiency of doubled haploid line production, resulting in smaller population sizes for selection of desirable traits in comparison to the single-seed descent method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 383-396 
    ISSN: 0197-8462
    Keywords: hematology ; immunology ; mice ; pulsed microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Mice were exposed in the far field in an anechoic chamber to 2,880-MHz pulsed microwaves 3 to 7.5 h daily, 5 days/week for 60 to 360 h. Three experiments were performed at average power densities of 5 mW/cm2 and six at 10 mW/cm2, corresponding to averaged specific absorption rates (SARs) of 2.25 and 4.50 mW/g, respectively. Each experiment consisted of eight mice, with a concurrently sham-exposed group of eight. In two of three studies at 5 mW/cm2, there was a significant increase in bone marrow cellularity in the microwave-exposed groups compared to the sham-exposed groups. Significant differences were occasionally seen in erythrocyte, leukocyte, and platelet values from microwaveexposed groups, but were not consistently observed. In one of six groups exposed at 10 mW/cm2, mean bone marrow cellularity was reduced significantly in the microwaveexposed mice; in another group, the lymphocyte count was increased. In only one exposure (10 mW/cm2 for 360 h) was any significant effect noted on serum proteins: a reduction to 5.1 ± 0.3 g/dl in the exposed versus 5.6 ± 0.4 g/dl in the sham-exposed mice. This was due to a decrease in alpha and beta globulins, with no effect on albumin or gamma globulin concentrations. No effect on bone marrow granulocyte/macrophage colony-forming units (CFU) was revealed following exposure of mice to pulsed microwaves at 5 mW/cm2. In one of four exposures at 10 mW/cm2, there was a significant increase in CFU-agar colonies. No significant effects of exposures at 10 mW/cm2 were observed on in vivo and in vitro assays of cell-mediated immune functions. No exposure-related histopathologic lesions were found from examination of several tissues and organs. Results of these series of exposures of mice at SARs of 2.25 and 4.50 mW/g indicated no consistent effects on the hematologic, immunologic, or histopathologic variables examined.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...