Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 16 (2005), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: The pattern of FF intervals during atrial fibrillation (AF) has been analyzed in induced and spontaneous AF episodes, after the induction of ventricular fibrillation (VF) and after atrial shock, in order to suggest practical considerations for AF management in patients implanted with antitachycardia devices. Methods: In 13 patients implanted with a dual-chamber defibrillator, FF intervals were analyzed during two separate induced AF episodes, before and after VF induction over AF, as well as during spontaneous AF episodes and after unsuccessful atrial shocks. The following parameters were considered: mean atrial cycle length (CL), atrial CL stability, and standard deviation of the atrial cycle. Results: The AF pattern had comparable characteristics considering two separate inductions of AF, as well as spontaneous AF episodes. Ventricular tachyarrhythmia induction resulted in a shortening of atrial CL (P 〈 0.02) and in a less organized AF pattern (P 〈 0.005). Changes in the FF interval after ineffective shock therapy showed a shortening of AF cycles after shocks with energies far below the defibrillation threshold. Conclusions: (a) The AF pattern is reproducible in separate inductions of sustained AF and in spontaneous episodes, (b) dynamic changes involving a shortening of the AF cycle and an evolution to a less homogeneous pattern occur after VF induction, revealing a complex interplay between AF and VF, and (c) FF interval analysis after ineffective shock delivery may allow the relationship between delivered shock energy and effective defibrillation energy to be estimated, thereby providing practical suggestions for step-up protocols in atrial cardioversion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 15 (2004), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Introduction: Biventricular pacing is an established treatment for congestive heart failure. Whether the anatomic location of the coronary sinus (CS) lead affects outcomes is unknown. The aim of this study was to evaluate the clinical response and mortality in patients who had transvenous CS leads placed in different anatomic branches for biventricular pacing. Methods and Results: We evaluated 233 consecutive patients with New York Heart Association (NYHA) class III–IV heart failure and ejection fraction 〈35% who had successful placement of a transvenous left ventricular lead through a CS venous branch. Patients were divided into two groups based on anatomic lead position. Group 1 (n = 66) included leads in the anterior and anterolateral branches. Group 2 (n = 167) included leads in the lateral and posterolateral branches. Postimplant, functional capacity improved from an average 3.1 to 2.7 in group 1 (P = 0.001) and from 3.1 to 2.3 in group 2 (P = 0.001). Left ventricular ejection fraction (LVEF) measured by transthoracic echocardiography did not improve significantly in group 1 (pre-LVEF 18%, post-LVEF 20%; P = NS) but increased significantly from 19% to 27% in group 2 (P = 0.008). Despite the difference in ejection fraction response, the mortality in the two groups after a mean follow-up of 546 days was similar (13.6% group 1 vs 17.9% group 2). Conclusion: Placement of the CS lead in the lateral and posterolateral branches is associated with significant improvement in functional capacity and greater improvement in left ventricular function compared with the anterior CS location. This improvement does not appear to influence mortality.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...