Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Annals of noninvasive electrocardiology 9 (2004), S. 0 
    ISSN: 1542-474X
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: Careful assessment of QT interval prolongation is required before novel drugs are approved by regulatory authorities. The choice of the most appropriate method of electrocardiogram (ECG) acquisition and QT/RR interval measurement in clinical trials requires better understanding of the differences among currently available approaches. This study compared standard and Holter-derived 12-lead ECGs for utility in detecting sotalol-induced QT/QTc and RR changes. Manual methods (digitizing pad and digital on-screen calipers) were compared for precision of QT and RR interval measurement. Methods and Results: Sixteen hundred pairs of serial 12-lead digital ECGs were recorded simultaneously by standard resting ECG device and by continuous 12-lead digital Holter over 3 days in 39 healthy male and female volunteers. No therapy was given on the 1st day followed by 160 mg and 320 mg of sotalol on the 2nd and 3rd day, respectively. Holter-derived and standard ECGs produced nearly identical sotalol-induced QT/QTc and RR changes from baseline, as did the manual digipad and on-screen caliper measurements. The variability of on-screen QT measurement in this study was greater than that of digipad. Conclusions: Digital 12-lead Holter and standard 12-lead ECG recorders, as well as the manual digitizing pad and digital on-screen calipers, are of equal utility for the assessment of drug-induced change from baseline in QT and RR interval, although the variability of the on-screen method in this study was greater than of the digipad.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für angewandte Mathematik und Physik 16 (1965), S. 337-344 
    ISSN: 1420-9039
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Physics
    Notes: Zusammenfassung Behandelt wird das Problem eines transversal isotropischen Körpers, der durch zwei konzentrische Kegelflächen begrenzt ist und durch eine asymmetrische Kraft an der Spitze belastet wird. Geschlossene Ausdrücke werden gegeben für den Spannungszustand und die Verformung. Ein interessanter Spezialfall ist das Cerruti-Problem, wo eine konzentrierte Kraft tangential an der Oberfläche eines elastischen Halbraumes wirkt. Die Lösung ist exakt im Rahmen der linearen Elastizitätstheorie.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗