Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 26 (1970), S. 447-455 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: Two programs have been developed to calculate the one-phonon thermal diffuse scattering included in measured integrated intensities of Bragg reflections for cubic crystals. Both include the anisotropy of the diffuse scattering correctly within the continuum elasticity approximation, and both allow an approximate inclusion of the effects of the wavelength distribution of the primary beam. One program, restricted to ω-scans, includes primary beam divergences approximately using three experimental reflection profiles to describe the weighting function in reciprocal space. The second program, applicable to both ω-scans and θ: 2θ-scans, neglects the primary beam divergences but has the advantage of being approximately two orders of magnitude faster than the first. Calculations have been made with these programs for several cases to illustrate the dependence of the included thermal diffuse scattering correction on various factors and to compare with the values obtained from previous approaches.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 25 (1969), S. 395-396 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: An expression is obtained for the spherically averaged acoustic phonon polarization and velocity factor found in theories of 1-phonon thermal diffuse scattering that is valid for all real cubic crystals and easy to evaluate numerically. A comparison with the usual approximate form shows appreciable discrepancies for very anisotropic materials.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 28 (1972), S. 572-580 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: The one-phonon thermal diffuse scattering in powder patterns of monatomic cubic materials has been investigated using a model that gives the correct frequencies and polarization vectors of the long-wavelength phonons for materials of arbitrary elastic anisotropy. Computer calculations have been made of the intensity distribution of this scattering and of the correction for its inclusion in measured integrated intensities of powder pattern reflections. Elastic anisotropy is found to produce marked differences, despite the powder pattern averaging; and, contrary to the Chipman–Paskin approximation, the integrated intensity correction is found generally not to vary smoothly with (h2 + k2 + l2) or linearly with scan length even for isotropic materials, as Suortti also noted. A much simpler method for calculating the integrated intensity correction has also been developed, based on a modified Warren model, that gives reasonably accurate values under most conditions even for very anisotropic materials and is several orders of magnitude faster than the primary method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : International Union of Crystallography (IUCr)
    Acta crystallographica 25 (1969), S. 209-214 
    ISSN: 1600-5724
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: The determination of an absolute scale for X-ray intensities involves the experimental evaluation of a number of constraints in the intensity equation whose values are not normally required. The absolute intensities so obtained will not be useful, in the present context, unless the overall accuracy can be maintained at about 1% or better. Some of the difficulties which can occur in making the measurements to the necessary accuracy are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...