Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: To develop polymer systems with improved lithographic resist properties, terpolymers of methyl methacrylate/methacrylonitrile/methyl α-chloroacryate (MMA/MCN/MCA), methyl methacrylate/methacrylonitrile/α-chloroacrylonitrile (MMA/MCN/ACAN), and methyl methacrylate/methacrylonitrile/vinylidene chloride (MMA/MCN/VDC) were prepared by emulsion polymerization. Also one methyl methacrylate/ methyl α-chloroacylate/α-chloroacrylonitrile (MMA/MCA/ ACAN) terpolymer was prepared. The radiation susceptibilities of these terpolymers were measured using the 60Coγ-irradiation method. Molecular weights were determined both by membrane osmometry and gel permeation chromatography. All terpolymers exhibited higher radiation-degradation susceptibilities than poly(methyl methacrylate). The Gs values did not follow the general trend, previously observed with MCN/MCA copolymers, of being directly proportional to the respective terpolymer compositions. In some cases, the addition of small quantities of α-chlorine-containing monomers caused Gx to increase. This observation greatly differs from those observed for copolymer systems such as MMA/MCA, MCN/MCA, MMA/ ACAN, etc. studied previously. Terpolymerization gives highly soluble polymers especially suitable for wet development by many solvents. This is an important consideration for polymers with high mole fractions of methacrylonitrile (MCN) or vinylidene chloride (VDC) which are rendered soluble in development solvents. The electron-beam sensitivities were obtained for samples of three classes of the terpolymers and they were higher than that of PMMA. For example, at 20Kev a 62/34/4 MMA/MCN/MCA terpolymer exhibited a sensitivity of 1.3 × 10-5 coulombs cm-2 at l/lo = 1. The introduction of ACAN narrows the working range for positive resist behavior. For example MMA/MCN/ACAN(41/40/19) has a sensitivity of 8.3 × 10-6 coulombs cm-2 at l/l0 = 0.6 but it crosslinks at 1 - 1.3 × 10- coulombs cm2. The MMA/MCN/VDC(21/76/3) polymer was about 25 times more sensitive than PMMA (7 × 10-6 C cm-2 at l/l0=1).
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Electron Microscopy Technique 10 (1988), S. 125-126 
    ISSN: 0741-0581
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Natural Sciences in General
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...