  • 1
    ISSN: 1432-0932
    Keywords: Key words Spine ; Interbody ; Fusion ; Compression ; Biomechanics ; Implant ; Posterior ; lumbar intervertebral fusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European spine journal 4 (1995), S. 114-122 
    ISSN: 1432-0932
    Keywords: Thoracic spine ; Biomechanics ; Pedicle screw ; Pedicle hook ; Pull-out test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Pedicle hooks which are used as an anchorage for posterior spinal instrumentation may be subjected to considerable three-dimensional forces. In order to achieve stronger attachment to the implantation site, hooks using screws for additional fixation have been developed. The failure loads and mechanisms of three such devices have been experimentally determined on human thoracic vertebrae: the Universal Spine System (USS) pedicle hook with one screw, a prototype pedicle hook with two screws and the Cotrel-Dubousset (CD) pedicle hook with screw. The USS hooks use 3.2-mm self-tapping fixation screws which pass into the pedicle, whereas the CD hook is stabilised with a 3-mm set screw pressing against the superior part of the facet joint. A clinically established 5-mm pedicle screw was tested for comparison. A matched pair experimental design was implemented to evauluate these implants in constrained (series I) and rotationally unconstrained (series II) posterior pull-out tests. In the constrained tests the pedicle screw was the strongest implant, with an average pull-out force of 1650 N (SD 623 N). The prototype hook was comparable, with an average failure load of 1530 N (SD 414 N). The average pull-out force of the USS hook with one screw was 910 N (SD 243 N), not significantly different to the CD hook's average failure load of 740 N (SD 189 N). The result of the unconstrained tests were similar, with the prototype hook being the strongest device (average 1617 N, SD 652 N). However, in this series the difference in failure load between the USS hook with one screw and the CD hook was significant. Average failure loads of 792 N (SD 184 N) for the USS hook and 464 N (SD 279 N) for the CD hook were measured. A pedicular fracture in the plane of the fixation screw was the most common failure mode for USS hooks. The hooks usually did not move from their site of implantation, suggesting that they may be well-suited for the socalled segmental spinal correction technique as used in scoliosis surgery. In contrast, the CD hook disengaged by translating caudally from its site of implantation in all cases, suggesting a mechanical instability. The differences in observed hook failure modes may be a function of the type and number of additional fixation screws used. These results suggest that additional screw fixation allows stable attachment of pedicle hooks to their implantation site. Hooks using additional fixation screws passing obliquely into the pedicle apparently provide the most rigid attachment. The second fixation screw of the prototype hook almost doubles the fixation strength. Thus, the prototype hook might be considered as an alternative to the pepdicle screw, especially in the upper thoracic region.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-0932
    Keywords: Thoracic spine ; Pedicle hook ; Fixation screw ; Biomechanics ; Pull-out test
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The pull-out force of thoracic spinal pedicle hooks secured by long fixation screws engaging the posterior portion of the vertebral endplate was measured. The perfomance of these hooks was compared with that of hooks using a shorter screw and different screw orientation such that the vertebral endplates were not perforated. The longer and differently angulated screws, engaging the endplate, significantly enhanced the fixation potential of the hooks.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...