Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 69 (1998), S. 519-526 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A fast method and compact device for mixing sub-microliter fluid samples contained in glass capillaries is presented. The fluid is rapidly moved back and forth by air volume displacement driven by a piezo-ceramic actuator. Rapid mixing of different fluids is achieved via diffusion between the main fluid volume in the capillary and the thin fluid film it deposits on the capillary wall through its motion. Bubbles in the fluid are processed out of the capillary by use of an asymmetric velocity profile. A simple analysis model is used to optimize the design of the device and to elucidate the mechanisms involved in mixing. The mixing time is found to be inversely proportional to the fraction of the fluid volume that is left in the film layer for each cycle, which is determined by the wetting properties and the viscosity. The mixing time is therefore controlled by the dead-air volume of the system, the fluid volume, the capillary size, and the displacement limits of the piezo-ceramic actuator, in addition to the intrinsic properties of the fluid being mixed. The device described can mix two 1 μl water solutions in under 3 s. The possible shear breakage of DNA in solution is investigated, and λ-DNA is found to remain intact at aggressive mixing parameters. No evidence of aerosol contamination in polymerase chain reaction reactions was found to date. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 13 (1977), S. 151-154 
    ISSN: 1432-1920
    Keywords: Meglumine iothalamate ; Conray ventriculography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Meglumine iothalamate, an iodinated contrast agent, is commonly used in humans for roentgenographic outlining of cerebral ventricles. Although clinical studies have shown meglumine iothalamate to be less toxic than other radiopaque materials, its microscopic effects on brain tissue have never been studied in a controlled manner. For this study canine cerebral tissue was exposed to intraventricular saline or saline plus meglumine iothalamate and the results were compared by light microscopy. Reactive changes were found in both groups. They occurred with greater frequency and degree in the group exposed to meglumine iothalamate, but permanent damage to brain tissue, did not occur.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...