Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of plastic surgery 22 (1999), S. 282-285 
    ISSN: 1435-0130
    Keywords: Key words Cleft sternum ; Ectopia cordis ; Skin flap ; Iliac bone
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  A case of sternal cleft is presented in which an iliac bone graft was used to repair a defect of the lower two-thirds of the sternum together with a local rotation flap for wound closure. A second operation was necessary due to loss of the flap tip. At 2-year follow-up there was some absorption of the grafted iliac bone. The pertinent literature is reviewed and therapeutic principles are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 25 (1991), S. 141-156 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: To evaluate an experimental inorganicbone-particle-impregnated bone cement, canine hip prostheses were implanted in dogs using a regular bone cement on one side and the experimental bone cement on the other. In a preliminary feasibility study, bone ingrowth into the resorbed bone-particle spaces was established 3 months after implantation in three dogs. In a more detailed study, twenty-eight (28) dogs were divided in four groups to delineate the effects of time on the phenomena of bony ingrowth. One month after implantation, active bone ingrowth into the bone cement was obvious. By 3 months postimplantation, the ingrowth appeared to have traversed the thickness of the bone-particle-impregnated cement. By the fifth month, most of the interconnected inorganic bone particles were replaced by new bone. At the end of a year, the ingrown bone was mature and negligible new bone activity was present. Biomechanical pushout tests closely corroborated the histologic observations. The maximum shear strength of the cement/bone interface of the experimental side reached 3.6 times that of the control side at 5 months postimplantation. No further improvements were seen at 12 months postimplantation. A viable bone/cement interface may result in a better orthopedic implant fixation system by combining the advantages of both cement for immediate rigidity and biological ingrowth for longterm stability.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...