Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Water, air & soil pollution 10 (1978), S. 187-198 
    ISSN: 1573-2932
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract The deposition rates for wet, dry, and integrated fallout of P to the southern portion of Lake Huron were determined. Samples were analyzed for water-soluble, acid (pH =2) soluble, and insoluble (bound) P. The term ‘available P’ was used to indicate the sum of the water- and acid-soluble fractions of P in each type of input. Of the integrated fallout samples, approximately one-third was present as available P. The deposition rate for dry fallout of available P was determined to be 1.7 ng cm−2 day−1. The wet deposition rate was estimated to be 2.2 ng cm−2 day−1 for available P. Total fallout of available P, determined from shore-based integrated fallout collectors, was calculated to occur at a rate of 6.5 ng cm−2 day−1. The difference between the wet-plus-dry deposition and the integrated deposition rates has been ascribed to the contamination of integrated fallout collectors by local sources (roads, agricultural activity, etc.) though attempts were made to minimize this problem. The presence of large quantities of biological material (pollen, algae, insect larvae) accounted for a large fraction of the difference observed, especially in the spring months.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 10 (1972), S. 193-200 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Recent literature reports from three laboratories have treated the refraction correction for the Sofica and a noncommercial light scattering photometer. Our re-evaluation of the data contained in these reports, as well as our experiments, indicate that the usually cited n2 refraction correction has not been unquestionably established for these instruments. In some cases, imprecise experimental techniques have been used to support this particular form of the correction. In addition, we find the optical system of the Sofica instrument results in the detector seeing vertically past the horizontal edge of the illuminated volume in violation of a basic assumption in the deduction of the n2 correction. Our experiments, as well as our interpretation of recent literature data, support an exponent of less than 2.0 for the Sofica apparatus, which is consistent with an instrument whose detector views outside the illuminated volume. However, the experimental methods available to evaluate the exponent lack the desired precision.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...