Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1619-7089
    Keywords: Single-photon emission tomography ; Technetium-99m hexamethylpropylene amine oxime ; Computed tomography ; Method of Mountz ; Supratentorial ischaemic infarction
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A comparative interim analysis was performed of clinical parameters, computed tomographic (CT) scan results and technetium-99m hexamethylpropylene amine oxime single-photon emission tomography (SPET) findings obtained within 12 h of acute supratentorial ischaemic infarction. First, the applicability for SPET semiquantification in this study of the “method of Mountz”, simultaneously accounting for extent and degrees of hypoperfusion by expressing deficits as millilitre of zero perfusion, was considered. Next, the relative contributions of perfusion SPET and CT scan in the acute stage of ischaemic infarction were compared in 27 patients (mean age 68.8 years). Finally, the correlation of SPET lesions with clinical parameters at onset was evaluated. The method of Mountz represents a workable, accurate virtual parameter, with the assumption that the contralateral brain region remains uninvolved. Interobserver reproducibility in 12 SPET studies, with lesions varying between 6 and 369 cc, showed a correlation coefficentr of 0.99. In practice, because of inconstant distribution of activities in the brain, the method can only be applied slice by slice and not on the total global volume. While the mean delay since the onset of symptomatology was approximately 7 h for both SPET and CT scan, SPET showed lesions concordant with the clinical neurological findings in 100% and CT scan in only 48%. One could hypothesize that SPET examinations performed later would show larger functional defects, because of the development of additional functional changes secondary to biochemical alterations. However, in this regard no statistically significant differences were found between two subproups, taking the median of delay before SPET examination as cut-off. Finally, when comparing the volumes of SPET lesions during the acute stage with clinical parameters, a statistically significant correlation (P〈0.01) was found with the Orgogozo Scale scores describing the neurological deficit, but not with the Glasgow Coma Scale or Frenchay Aphasia Screening Test scores obtained on admittance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...