    Keywords: Key words: Thyroid cancer ; Fluorine-18 fluorodeoxyglucose ; Positron emission tomography ; Sestamibi ; Radioiodine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: n =222) and the group with negative radioiodine scan (n=166), respectively. Specificity was 90% in the whole patient group. Sensitivity and specificity of WBS were 50% and 99%, respectively. When the results of FDG-PET and WBS were considered in combination, tumour tissue was missed in only 7%. Sensitivity and specificity of MIBI/Tl were 53% and 92%, respectively (n=117). We conclude that FDG-PET is a sensitive method in the follow-up of thyroid cancer which should be considered in all patients suffering from differentiated thyroid cancer with suspected recurrence and/or metastases, and particularly in those with elevated thyroglobulin values and negative WBS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Cost-effectiveness Economics Pulmonary nodule Lung cancer Positron emission tomography Fluorodeoxyglucose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Management of solitary pulmonary nodules (SPNs) of up to 3 cm was modelled on decision analysis comparing "wait and watch", transthoracic needle biopsy (TNB), exploratory surgery and full-ring dedicated positron emission tomography (PET) using fluorine-18 2-fluorodeoxyglucose (FDG). The incremental cost-effectiveness ratios (ICERs) were calculated for the main risk group, a cohort of 62-year-old men, using first "wait and watch" and second exploratory surgery as the baseline strategy. Based on published data, the sensitivity and specificity of FDG-PET were estimated at 0.95 and 0.80 for detecting malignancy in SPNs and at 0.74 and 0.96 for detecting metastasis in normal-sized mediastinal lymph nodes. The costs quoted correspond to reimbursement in 1999 by the public health provider in Germany. Decision analysis modelling indicates the potential cost-effectiveness of the FDG-PET strategy for management of SPNs. Taking watchful waiting as the low-cost baseline strategy, the ICER of PET [3218 euros (EUR) per life year saved] was more favourable than that of exploratory surgery (4210 EUR/year) or that of TNB (6120 EUR/year). Changing the baseline strategy to exploratory surgery, the use of PET led to cost savings and additional life expectancy. This constellation was described by a negative ICER of –6912 EUR/year. The PET algorithm was cost-effective for risk and non-risk patients. However, the ICER of PET as the preferred strategy was sensitive to a hypothetical deterioration of any PET parameters by more than 0.07. To transfer the diagnostic efficacy from controlled studies to the routine user and to maintain the cost-effectiveness of this technology, obligatory protocols for data acquisitions would need to be defined. If the prevalence of SPNs is estimated at the USA level (52 per 100,000 individuals) and assuming that multiple strategies without PET are the norm, the overall costs of a newly implemented PET algorithm would be limited to far less than one EUR per member of the public health provider in Germany.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1619-7089
    Keywords: Cost-effectiveness Economics Lung cancer Positron emission tomography Fluorodeoxyglucose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Decision analysis is used here to establish the most cost-effective strategy for management of potentially operable non-small cell lung cancers (NSCLCs). The strategies compared were conventional staging (strategy A), dedicated systems of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) in patients with normal-sized (strategy B) or in patients with enlarged mediastinal lymph nodes (part of strategy C), and FDG-PET followed by exclusion from surgical procedures when both computed tomography (CT) and PET were positive for mediastinal lymph nodes (strategy D) or when PET alone was positive (strategy E). Based on published data, the sensitivity and specificity of FDG-PET were estimated at 0.74 and 0.96 for detecting metastasis in normal-sized mediastinal lymph nodes, and at 0.95 and 0.76 when these lymph nodes were enlarged. The calculated probability of up-staging to M1 by using PET was 0.05. The costs quoted correspond to the cost reimbursed in 1999 by the public health provider in Germany. The incremental cost-effectiveness ratio (ICER) of strategy B was much more favourable (143 EUR/LYS; LYS = life year saved) than the ICER of strategy C (36,667 EUR/LYS). In strategy B, the use of PET did not raise the overall costs because the costs of PET were almost balanced by a better selection of patients for beneficial cancer resection. The exclusion from biopsy confirmation in strategies D and E led to cost savings that did not justify the expected reduction in life expectancy. In sensitivity analyses, the ICERs of strategy B were robust to the pretest likelihood of N2/N3, to penalized test parameters of PET and to reimbursement of PET. However, the ICER of strategy B would be raised to 28,000 EUR/LYS through use of thoracic PET without whole-body scanning. To conclude, the implementation of whole-body PET with a full ring of detectors in the preoperative staging of patients with NSCLC and normal-sized lymph nodes is clearly cost-effective. However, patients with nodal-positive PET results should not be excluded from biopsy.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1619-7089
    Keywords: Key words: Technetium-99m methoxyisobutylisonitrile – Iterative reconstruction – Parathyroid adenoma – Primary hyperparathyroidism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The purpose of this study was to assess the value of technetium-99m methoxyisobutylisonitrile (MIBI) single-photon emission tomography (SPET) and an iterative reconstruction algorithm for the preoperative localisation of parathyroid adenomas (PTAs). Seventy-two patients (26 male, 46 female, mean age 58±16 years) with known primary hyperparathyroidism were examined preoperatively. First, a thyroid examination was performed to detect possible MIBI-accumulating thyroid lesions. Planar scans were then acquired 15 and 120 min and tomographic images 120 min after intravenous injection of 740 MBq 99mTc-MIBI, using a triple-head gamma camera (Picker Prism 3000). Additionally, 99mTc-MIBI/ 99mTc-pertechnetate subtraction scintigraphy of the early planar images was performed. The SPET data were evaluated using an iterative reconstruction (multiplicative iterative SPET reconstruction: MISR) as well as a standard algorithm (FBP: filtered back-projection with application of a 3-D low-pass postfilter). The weight of the resected PTAs ranged from 110 mg to 5 g. Using planar MIBI scans, correct localisation of the side of the PTA was possible in 81% of cases (58% for PTAs weighing less than 500 mg). Sensitivity increased to 94% using SPET and FBP, while with MISR it rose further, to 97%. Patients with PTAs weighing less than 500 mg showed a sensitivity of 88% with MISR and 81% with FBP. Furthermore, there was a clear improvement in image quality using MISR. None of the normal parathyroid glands were visualised. This study indicates that, in comparison with planar scintigraphy, 99mTc-MIBI SPET is a more sensitive and specific tool for topographical localisation of PTAs, especially those that are small. There is a further improvement in sensitivity and image quality when iterative reconstruction is used instead of FBP.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    European journal of nuclear medicine 26 (1999), S. 663-680 
    ISSN: 1619-7089
    Keywords: Key words: Cost-effectiveness ; Cost-utility ; Nuclear medicine ; Imaging ; Radiopharmaceuticals
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The guidelines for publishing economic evaluations require a statement of the economic importance of the analysis and the viewpoint from which it has been carried out, as well as specification of at least two alternative programmes or interventions, the form of economic evaluation, the outcome measure, the method of costing, the time horizon and adjustment for timing of costs and benefits (e.g. by a discount factor), and the allowance for uncertainties (e.g. by implementation of a sensitivity analysis). The decision analysis can be based on clinical trial data, on retrospective or administrative databases, or on modelling. The choice of outcome measures is the key issue in an economic evaluation. In cost-effectiveness analysis, benefits are usually measured in natural units. This is the form of economic evaluation most frequently used in nuclear medicine. Endpoints of effectiveness applied in studies in this field have been procedures avoided, procedures initiated, cardiac events, survival probability, morbidity, quality of life and protracted or failed surgical procedures. In other instances, surrogate endpoints have been used such as metastases detected, staging, viability or tumour response. This, however, limits comparability of cost-effectiveness considerably, as proof of a change in the health outcome cannot be obtained. Measures of utility such as QALYs (quality-adjusted life years) have so far only been applied for decision tree analysis. Useful examples of economic evaluation studies in nuclear medicine are presented here for fluorodeoxyglucose positron emission tomography (FDG-PET) in the preoperative staging of non-small cell lung cancer, for FDG-PET in differentiating indeterminate solitary pulmonary nodules, for somatostatin receptor scintigraphy in detecting metastases of carcinoid tumours, for routine preoperative scintigraphy with sestamibi in patients with parathyroid adenoma, for periodic measurement of thyroid-stimulating hormone in detecting mild thyroid failure, for diagnostic algorithms including a lung scan in patients with suspected pulmonary embolism, for myocardial perfusion imaging as an incremental prognostic factor in patients with coronary artery disease, and for the use of radioiodine as first-line therapy of Graves’ hyperthyroidism and of toxic nodular goitres. Further evaluations of effectiveness or utility should be carried out within a multidisciplinary framework to ensure that nuclear medical procedures are included in the general management guidelines.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1619-7089
    Keywords: Key words: Thyroid cancer ; Fluorine-18 fluorodeoxyglucose positron emission tomography ; Radioiodine ; Scintigraphy ; Therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Metastases of differentiated thyroid cancer may show different uptake patterns for fluorine-18 fluorodeoxyglucose and [131I]NaI. FDG positron emission tomography (PET), iodine-131 whole-body scintigraphy (131I WBS) and magnetic resonance imaging were performed in 58 unselected patients, and spiral computed tomography (CT) of the lung in 25 patients. Thirty-eight patients presented with papillary carcinomas, 15 patients with follicular carcinomas and five patients with variants of follicular carcinoma. Primary tumour stage (pT) was pT1 in 3, pT2 in 19, pT3 in 11 and pT4 in 25 cases. For the detection of metastases, FDG PET was found to have a sensitivity of 50%, 131I WBS a sensitivity of 61%, and the two methods combined a sensitivity of 86%. When FDG PET was limited to patients with elevated thyroglobulin (Tg) levels and negative 131I WBS, the sensitivity of this algorithm was 82%. Of the 21 patients with lymph node metastases, seven presented with FDG uptake but no iodine uptake. In four of them, a second FDG hot spot appeared in a lymph node metastasis of normal size. Five of the seven patients underwent surgery. None of the eight patients with pulmonary metastases smaller than 1 cm exhibited FDG uptake, while five of them had iodine uptake. All had positive results on spiral CT. In conclusion, FDG PET cannot be substituted for 131I WBS. If the Tg level is elevated and 131I WBS is negative, FDG PET can be used to detect lymph node metastases and complements anatomical imaging. A spiral CT of the lung is useful to exclude pulmonary metastases before planning a dissection of iodine-negative lymph node metastases.